Wiki source code of ReleaseNotes

Version 6.1 by Bram Ardesch on 2023/05/23 16:11

Show last authors
1 == Changes and updates: ==
2
3 **05-04-2023**
4
5 (% class="table-hover" %)
6 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
7 **Change/Add/**
8
9 **Delete**
10 )))|**DB Type
11 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
12 |HDOP| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
13 MpHDOP
14 )))
15 |VDOP| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
16 MpVDOP
17 )))
18 |PDOP| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
19 MpPDOP
20 )))
21 |Number of satellites used| |Field to note the amount of sattelites that where used for the GPS measurement in this measurement point.|Add|Integer|tblMeasurementPoints|(((
22 MpNumberOfSatellites
23 )))
24 |HRMS| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
25 MpHRMS
26 )))
27 |VRMS| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
28 MpVRMS
29 )))
30 |(((
31 Gps pole height (m)
32 )))| |(((
33 Field to fill in the height of the GPS pole
34 )))|Add|Float|tblMeasurementPoints|(((
35 MpGPSPoleHeight
36 )))
37 |(((
38 Antenna height (cm)
39 )))| |(((
40 Field to fill in the height of the antenna on the GPS machine
41 )))|Add|Float|tblMeasurementPoints|(((
42 MpAntennaHeight
43 )))
44 |Weather conditions| |(((
45 Field to fill in the weather conditions during the drilling process
46 )))|Add|Float|tblMeasurementPoints|MPWeatherConditions
47 |Ambient temperature (°C) | |(((
48 Outside temperature during the drilling process
49 )))|Add|Float|tblMeasurementPoints|(((
50 MpAmbientTemperature
51 )))
52 |(((
53 CO (ppm)
54 )))| |(((
55 Field to save the measurement of carbon monoxide in the layer
56 )))|Add|Float|tblLayers|LaCO
57 |(((
58 Oxygen ~(%)
59 )))| |(((
60 Field to save the measurement of oxygen in the layer
61 )))|Add|Float|tblLayers|(((
62 LaOxygenPercentage
63 )))
64 |(((
65 H2S (ppm)
66 )))| |Field to save the measurement of hydrogen sulfide in the layer|Add|Float|tblLayers|(((
67 LaH2S
68 )))
69 |(((
70 LEL ~(%)
71 )))| |(((
72 Field the save the lower explosive level measurement in the layer
73 )))|Add|Float|tblLayers|(((
74 LaLEL
75 )))
76 |Inspectie efficiency ~(%)| |The amount of soil in the layer that was able to be inspected properly for the purpose of asbestos research.|Add|Float|tblLayers|(((
77 LaInspectionEfficiencyPercentage
78 )))
79 |Mixing of soil| |(((
80 Field to denote the amount of mixing in this soil layer
81 )))|Add|Integer (codelist 291)|tblLayers|(((
82 LaDegreeOfSoilMixingCode
83 )))
84 |(((
85 CO (ppm)
86 )))| |(((
87 Field to save the measurement of carbon monoxide in the air sample
88 )))|Add|Float|tblObservations|METINGCODE 161
89 |Jar type| |Soil sample ring added to the codelist|Add codelist value| | |
90
91 **25-11-2022:**
92
93 (% class="table-hover" %)
94 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
95 **Change/Add/**
96
97 **Delete**
98 )))|**DB Type
99 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
100 |Status| |(((
101 This field is for planned measurement points, and can be used to determine the status (to be done, done, removed etc)
102 )))|Add|Lookup value (codelist 289)|tblMeasurementPoints|(((
103 MpStatusCode
104 )))
105 |(((
106 Penetrometer compaction strength (kg/cm2)
107 )))| |(((
108 This field is a numeric field for field tests to determine the compaction strength of the soil
109 )))|Add|numberfield|tblMeasurementPoints|MpPenetrometerCompaction
110 |(((
111 Accreditation number
112 )))| |(((
113 This field can be used to fill in the accreditation number of the fieldworker, which needs to be filled in by walloon customers
114 )))|Add|text field (30)|tblMeasurementPoints|(((
115 MpAccreditationNumber
116 )))
117 |Moisture Class Soil| |(((
118 This field is for giving moisture classes in soil, these are present in the NEN 6693 and also used for french research.
119 )))|Add|Lookup value (codelist 290)|tblLayers|(((
120 LaMoistureClass
121 )))
122 |Sediment Sump Length (cm)| |(((
123 Field to input the length within the tube that is used as a sand / silt catchment below the filter
124 )))|Add|numberfield|tblFilterTubes|FtSedimentSumpLength
125 |Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblMeasurementPoints|(((
126 MpTrialPitLength & MpTrialPitWidth
127 )))
128 |Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblLayers|(((
129 LaTrialPitLength & LaTrialPitWidth
130 )))
131 |Initial function| |(((
132 Field to input the function of the filtertube when it was installed
133 )))|Add|Lookup value (codelist 288)|tblFilterTubes|FtInitialFiltertubeFunction
134 |Weather conditions| |(((
135 Remarkable weather conditions can be noted here as part of a location inspection
136 )))|Add|String|tblSublocations|(((
137 SlCoverRatePostRemoval
138 )))
139 |Sampling procedure| |Field to fill in the used sampling procedure|Add|Lookup value (codelist 287)|tblWatersamples|WsSamplingProcedure
140 |Starttime & Endtime sampling|Already existed for airsamples, no as well for watersamples| |Change|Datetime|tblWatersamples|(((
141 WsStartSampleTime & WsPostSampleTime
142 )))
143 |Radioactive ionisation (cps)| |(((
144 Numberfield to input the cps (counts per second) of a meter that reacts to ionisation (like a geiger counter)
145 )))|Add|numberfield|tblJars|(((
146 JrIonisationCount
147 )))
148 |Sample water content ~(%)| |(((
149 Percentage field for sample humidity
150 )))|Add|numberfield|tblJars|JrHumidityPercentage
151 |(((
152 Volume weight dry Yd (Kn/M3)
153 )))| |(((
154 Geotechnical field for the dry weight of the sample, different unit than the other weight sample fields which are more simplistic
155 )))|Add|numberfield|tblJars|JrDryVolumeWeight
156 |Liquit limit water content ~(%)| |The liquid limit used within the attenbergs limits|Add|numberfield|tblJars|JrLiquidLimit
157 |Plasticity index ~(%)| |(((
158 Geotechnical field for the plasticity index
159 )))|Add|numberfield|tblJars|JrPlasticityIndex
160 |(((
161 Semi-Solid limit (water content %)
162 )))| |The semi-solid limit used within the attenbergs limits|Add|numberfield|tblJars|JrSemiSolidLimit
163 |(((
164 Plastic limit (water content %)
165 )))| |The plastic limit used within the attenbergs limits|Add|numberfield|tblJars|JrPlasticLimit
166 |(((
167 Undrained shear strength (kPa)
168 )))| |The shear strength of the soil|Add|numberfield|tblJars|JrUndrainedShearStrength
169 |Void ratio ~(%)| |The ratio of void (air) in the soil|Add|numberfield|tblJars|JrVoidRatio
170 |Saturation ~(%)| |The percentage of moisture saturation in the soil|Add|numberfield|tblJars|JrSaturationPercentage
171 |Soil sampes (several fields)|Multi edit turned on| |Change| |tblJars|Several
172 |Destination Type| |Field for destination type for the OVAM|Add|Lookup value (codelist 49)|tblProjects|PrDestinationType
173 |Groundwater vulnerability| |Field for groundwater vulnerability for the OVAM|Add|Lookup value (codelist 92)|tblProjects|PrGroundwaterVulnerability
174 |Percentage Fractrion >20mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaCourseFractionPercentage
175 |Weight fraction >20 mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaCourseFractionWeight
176 |Weight fraction <20 mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaFineFractionWeight
177 |Type plate material| |Asbestos fields now als on layer level|Add|Lookup value (281)|tblLayers|LaPlateMaterialTypeCode
178 |Number of pieces plate material| |Asbestos fields now als on layer level|Add|numberfield|tbLLayers|LaPlateMaterialPieces
179 |Weight plate material (g)| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaPlateMaterialWeight
180 |Special component gradation|Add codelist "A little (bit of)"| |Add Codelist value| | |
181 |Sand sorting codes|Add extra sand and gravel sorting codes| |Add Codelist value| | |
182 |Geological interpretation|All new belgium geological interpretation options added| |Add Codelist value| | |
183 |End prepump citeria|New prepump ending condition added| |Add Codelist value| | |
184 |Finishing Type|Type 'Asfalt' added| |Add Codelist value| | |
185 |Project Type|New French Project types added| |Add Codelist value| | |
186 |Colour Type|Colour 'Pink' added| |Add Codelist value| | |
187 |Use of location|Additional location uses added| |Add Codelist value| | |
188
189 **03-08-2022:**
190
191 (% class="table-hover" %)
192 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
193 **Change/Add/**
194
195 **Delete**
196 )))|**DB Type
197 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
198 |Special or invasive vegetation(1, 2, 3)| |Field to note invasive species found on the release location. New codelist with species from the dutch invasive species list added.|Add|Lookup value (codelist 285)|tblSublocations|(((
199 SlSpecialVegetationCode
200 )))
201 |Sieved material inspection hole| |Field to note the total amount of sieved material at the measurementpoint level of an asbestos inspection hole|Add|Float|tblMeasurementPoints|MpSievedMaterial
202 |Water depth (cm-gl)| |Field to describe the column of water above the waterbed, if chosen not to add a water layer as the first layer.|Add|Float|tblMeasurementPoints|MpWaterDepth
203 |Special component in layer (mass%)| |Can be used to note the total mass % of foreign (non-soil) material in a layer.|Add|Float|tblLayers|LaSpecialComponentPercent
204 |Suspected Asbestos pollution| |Field by which a fieldworker can remark if a layer is suspect of containing asbestos|Add|Lookup value (codelist 73)|tblLayers|LaSuspectedAsbestosCode
205 |Measurement point type|New codelist options added|Canister, Ambient air measurement added|Change|Lookup value (codelist 24)|tblMeasurementpoints|MpTypeCode
206 |Reference plane|New codelist options added|Sea level added|Change|Lookup value (codelist 15)|tblMeasurementpoints|MpReferencePointTypeCode
207 |Finishing Type|New codelist options added|Surface box plasic, Surface box stainless steel added|Change|Lookup value (codelist 32)|tblFinishings|FiTypeCode
208 |Horizon|New codelist options added|Unit R0, Unit R1, Unit R2 added|Change|Lookup value (codelist 109)|tblLayers|LaHorizonCode
209 |Soil / Rock Type|New codelist options added|Granodiorite added|Change|Lookup value (codelist 163 and 35)|tblLayers|LaRockTypeCode
210 |Special component type|New codelist options added|(((
211 Construction and demolition waste, Calcium nodules, calcium crusts, Stones >50MM added
212 )))|Change|Lookup value (codelist 11)|tblLayers|LaSc1TypeCode
213 |Drilling System|New codelist options added|Tubed edelman, tubed pulse drill, tubed percussion gouge added|Change|Lookup value (codelist 23)|tblLayers|LaDrillingSystemTypeCode
214 |Clarity|New codelist options added|None, Low, medium, high clarity codes added|Change|Lookup value (codelist 252)|tblWatersamples|LaClarityCode
215 |Stop prepumping|New codelist options added|1x volume of drilling well + parameters stabilisation added|Change|Lookup value (codelist 200)|tblWatersamples|WsPrepumpingEndedTypeCode
216 |Sampling method|New codelist options added|multi support active sampling|Change|Lookup value (codelist 259)|tblWatersamples|WsSamplingMethodCode
217 |Placed in serie|New codelist options added|New codelist: Unique, in paralel, in series added|Change|Lookup value (codelist 284)|WsPackagings|BoPlacedInSerie
218 |Air sample Type|New codelist options added|Impregnated filter added|Change|Lookup value (codelist 272)|WsPackagings|BoSampleTypeCode
219 |Field matrix|New codelist options added|Waterbed (solid part) added|Change|Lookup value (codelist 6)|WsAnalysisSamples|MatrixTypeCode
220
221 **27-01-2022:**
222
223 (% class="table-hover" %)
224 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
225 **Change/Add/**
226
227 **Delete**
228 )))|**DB Type
229 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
230 |Use of location| |To add the current use of the location to a measurement point|Add|Lookupvalue|tblMeasurementPoints|MpLocationUsageCode
231 |Type|New codelist optios added |-|Change|Lookupvalue|tblMeasurementPoint|MpType
232 |Interior location| |Yes / no field for if the sample is an interior location|Add|Lookupvalue|tblMeasurementPoints|MpIsIndoorsCode
233 |FlowTypesSurfaceWater| |Describes the flowing pattern of the surface water sampling location|Add|Lookupvalue|tblObservations|METINGCODE 148
234 |Location flow rate| |The flow rate of the sampling location|Add|Lookupvalue|tblObservations|METINGCODE 149
235 |Special conditions| |Remark field for special sampling conditions to print in report|Add|String|tblWatersamples|JrStreamlineGUID
236 |Pump type|Codelist used for several fields|New options added to codelist|Change|Lookupvalue|Multiple fields|Multiple fields
237 |Pump connection| |Field for the power connection of a pump|Add|LookupValue|tblObservations|METINGCODE 150
238 |Matrix| |Added codelist options|Change|Lookupvalue|tblWatersamples|WsMatrix
239 |Mesh size (mm)| |Field for the mesh size of a monitoring well filter|Add|Float|tblFiltertubes|FtMeshSize
240 |Type|Project level|New codelist options|Change|Lookupvalue|tblProjects|PrType
241 |Type|Finishing level|New codelist options|Change|Lookupvalue|tblFinishings|FiType
242 |Measurement duration| |Field for the duration of a series of a measurements, mostly used to estimate the time when a tube is dry|Add|Float|tblObservations|METINGCODE 154 (Series), METINGCODE 153 (Stable value)
243 |Pumped volume series| |Field for the total pumped volume during a single series|Add|Float|tblObservations|METINGCODE 152 (Series), METINGCODE 151 (Stable value)
244
245 **22-11-2021:**
246
247 |**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
248 | | | | | | | | | |
249 |Soil samples|Length core sampler|Lengte steekbuis (mm)|Length core sampler (mm)|The length of a core sampler may vary and defines volume| |Add|Integer|tblJars|JrLengthCoreSampler
250 |Measurement Point|Diameter|Diameter (mm)|Diameter (mm)|(% colspan="2" %)Information is available on layer level, but may sometimes be consistent over the entire measurement point|Add|Integer|tblMeasurementPoints|MpDiameter
251 |Air Samples packaging|Placed in serie|In serie geplaatst|Yes/no|Two packages for air samples can be placed in serie or not| |Add|Lookupvalue (Yes/No)|tblBottles|BoPlacedInSerie
252 |Water samples|Surrounding humidity|Omgevingsvochtigheid|Licht vochtig, Zeer vochtig, Vochtig op bodem, Vochtig op plaatsen|The circumstances when sampling| |Add|Codelist|(((
253 * tblObservations
254 * tblWatersampleMeasurements
255 )))|Metingcode: 147 / WsSurroundingHumidity
256
257 **18-10-2021:**
258
259 |=(% colspan="1" rowspan="1" %)(((
260 **Labeltext in English**
261 )))|=(% colspan="1" rowspan="1" %)(((
262 **Remarks**
263 )))|=(% colspan="1" rowspan="1" %)(((
264 **Definition and process how this field will be used and when it will be filled.**
265 )))|=(% colspan="1" rowspan="1" %)(((
266 **Change/Add/Delete**
267 )))|=(% colspan="1" rowspan="1" %)(((
268 **DB Type**
269 **(String (length) / Float / Lookupvalue / Integer / DateTime)**
270 )))|=(% colspan="1" rowspan="1" %)(((
271 **DBTable in dsFieldProject**
272 )))|=(% colspan="1" rowspan="1" %)(((
273 **DBFieldname in dsFieldProject**
274 )))
275 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblProjects|(% colspan="1" rowspan="1" %)PrStreamlineGUID
276 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpStreamlineGUID
277 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblWaterSample |(% colspan="1" rowspan="1" %)WsStreamlineGUID
278 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFiltertubes|(% colspan="1" rowspan="1" %)FtStreamlineGUID
279 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLayers|(% colspan="1" rowspan="1" %)LaStreamlineGUID
280 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrStreamlineGUID
281 |(% colspan="1" rowspan="1" %)PackagingStreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrPackagingStreamlineGUID
282 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFinishings|(% colspan="1" rowspan="1" %)FiStreamlineGUID
283 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoStreamlineGUID
284 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLocations|(% colspan="1" rowspan="1" %)LcStreamlineGUID
285 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblSublocations|(% colspan="1" rowspan="1" %)SlStreamlineGUID
286
287 **07-10-2021:**
288
289 |=(% colspan="1" rowspan="1" %)(((
290 **Screen to add the extra field**
291 )))|=(% colspan="1" rowspan="1" %)(((
292 **Labeltext in English**
293 )))|=(% colspan="1" rowspan="1" %)(((
294 **Labeltext in Dutch**
295 )))|=(% colspan="1" rowspan="1" %)(((
296 **Examples of values and how it should be printed in a report.**
297 )))|=(% colspan="1" rowspan="1" %)(((
298 **Definition and process how this field will be used and when it will be filled.**
299 )))|=(% colspan="1" rowspan="1" %)(((
300 **Change/Add/Delete**
301 )))|=(% colspan="1" rowspan="1" %)(((
302 **DB Type**
303 **(String (length) / Float / Lookupvalue / Integer / DateTime)**
304 )))|=(% colspan="1" rowspan="1" %)(((
305 **DBTable in dsFieldProject**
306 )))|=(% colspan="1" rowspan="1" %)(((
307 **DBFieldname in dsFieldProject**
308 )))
309 |(% colspan="1" rowspan="1" %)Measurement Points Details|(% colspan="1" rowspan="1" %)Sample Moisture|(% colspan="1" rowspan="1" %)Monstervochtigheid|(% colspan="1" rowspan="1" %)Dried out|(% colspan="1" rowspan="1" %)Explains humidity condition of measurment point|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpSampleHumidityCode
310 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Special conditions|(% colspan="1" rowspan="1" %)Bijzondere omstandigheden|(% colspan="1" rowspan="1" %)Normal, used standard protocol|(% colspan="1" rowspan="1" %)Description of deviation from protocol|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsSpecialConditions
311 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Field conditions|(% colspan="1" rowspan="1" %)Maaiveld omstandigheden|(% colspan="1" rowspan="1" %)Damp, easy to drill|(% colspan="1" rowspan="1" %)Description of field/location at time of sampling|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsFieldConditions
312 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - O2|(% colspan="1" rowspan="1" %)Kalibratie Zuurstof ~(%)|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 136 / WsCalibrationO2
313 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - CO2|(% colspan="1" rowspan="1" %)Kalibratie koolstofdioxine/CO2 (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 137 / WsCalibrationCO2
314 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Start-sampling time|(% colspan="1" rowspan="1" %)Tijdstip start bemonstering|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %)Time when the actual sampling has started|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsStartSampleTime
315 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling time|(% colspan="1" rowspan="1" %)Tijdstip einde monstername|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsPostSampleTime
316 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post- sampling O2|(% colspan="1" rowspan="1" %)Zuurstof einde monstername |(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 140 / WsPostSampleO2
317 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling CO2|(% colspan="1" rowspan="1" %)Koolstofdioxine/CO2 einde monstername  (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 141 / WsPostSampleCO2
318 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling air flow rate|(% colspan="1" rowspan="1" %)Debiet einde monstername |(% colspan="1" rowspan="1" %)0,3l/min|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 142 / WsPostSampleFlowRate
319 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling PID|(% colspan="1" rowspan="1" %)PID einde monstername |(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 143 / WsPostSamplePID
320 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling temperature|(% colspan="1" rowspan="1" %)Temperatuur einde monstername|(% colspan="1" rowspan="1" %)25C|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 144 / WsPostSampleTemperature
321 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air humidity|(% colspan="1" rowspan="1" %)Vochtigheid einde monstername|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 145 / WsPostSampleHumidity
322 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air pressure|(% colspan="1" rowspan="1" %)Luchtdruk einde monstername|(% colspan="1" rowspan="1" %)25hPa|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 146 / WsPostSamplePressure
323 |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode
324 |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber
325
326
TerraIndex
asd