Show last authors
1 == Changes and updates: ==
2
3 **26-07-2023**
4
5 (% class="table-hover" %)
6 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
7 **Change/Add/**
8
9 **Delete**
10 )))|**DB Type
11 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
12 |Name inspector| |Field where the name of the fieldworker that performed the field inspection can be selected.|Add|String|tblSublocations|SlNameInspector
13 |Coverage removed?| |Yes/No field to indicate whether or not any vegetation was removed in order to perform a field inspection.|Add|Lookupvalue (73)|tblSublocations|(((
14 SlCoverageRemoved
15 )))
16 |(((
17 Density (ton/m3)
18 )))| |Field where the name of the fieldworker that performed the field inspection can be selected.|Add|Float|tblLayers|LaDensity
19 |pH-value| |Field to enter the measured Ph value of this soil layer. Often used to map out contamination from drug waste.|Add|Float|tblLayers|LaPhValue
20 |CH4 (ppm)| |The CH4 (methane) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 162
21 |(((
22 CO (ppm)
23 )))| |The CO (Carbonmonoxide) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 161
24 |CH4 (ppm) Series value| |The CH4 (methane) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 162
25 |(((
26 CO (ppm) Series value
27 )))| |The CO (Carbonmonoxide) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 161
28 |(((
29 Reference of the Flow-measurement device
30 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|WsDebitReference
31 |(((
32 Reference of the explosimeter
33 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
34 WsExplosimeterReference
35 )))
36 |(((
37 Reference of the barometer
38 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
39 WsBarometerReference
40 )))
41 |(((
42 Reference of the O2/ Co2 sensor
43 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
44 WsOxygenSensorReference
45 )))
46 |(((
47 Reference PID-instrument
48 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
49 WsPIDMeterReference
50 )))
51 |(((
52 Reference of the hygrometer
53 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
54 WsHygrometerReference
55 )))
56 |(((
57 Reference of the pump
58 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
59 WsPumpReference
60 )))
61 |(((
62 Drilling fluid used
63 )))| |If a fluid was used to aid the drilling, that fluid can be specified in this field. Required by Spanish ENAC standards.|Add|Lookupvalue (293)|tblMeasurementPoints|(((
64 MpDrillingFluid
65 )))
66 |(((
67 Reference PID-instrument
68 )))| |The referencecode of the used PID-instrument.|Add|String|tblMeasurementPoints|(((
69 MpPIDReference
70 )))
71 |(((
72 Gravel grain size from (mm)
73 )))| |The median of the type of gravel that has been used in the finishings of a filtertube.|Add|Float|tblFinishings|(((
74 FiGravelSizeFrom
75 )))
76 |Gravel grain size to (mm)| |The median of the type of gravel that has been used in the finishings of a filtertube.|Add|Float|tblFinishings|(((
77 FiGravelSizeTo
78 )))
79 |(((
80 Type of rod grease used
81 )))| |The type of grease used to connect different parts of the filtertubes.|Add|Lookupvalue (295)|tblFilterTubes|(((
82 FtRodGrease
83 )))
84 |(((
85 Reference of the purging water filter
86 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
87 WsFilterReference
88 )))
89 |(((
90 Reference of the multi-parameter sensor
91 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
92 WsMultiParameterSensorReference
93 )))
94 |(((
95 Reference of the waterlevel sensor
96 )))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
97 WsGroundwaterSensorReference
98 )))
99 |(((
100 n/a
101 )))| |Technical field for the exchange of field samples (air / water)|Add|GUID|tblWatersamples|WsFieldSampleGuid
102 |Reason| |Field t indicate the reason for starting the research|Add|Lookupvalue (294)|tblSummaryConclusion|(((
103 SmReasonCode
104 )))
105 | | | | | | |
106
107
108 **05-04-2023**
109
110 (% class="table-hover" %)
111 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
112 **Change/Add/**
113
114 **Delete**
115 )))|**DB Type
116 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
117 |HDOP| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
118 MpHDOP
119 )))
120 |VDOP| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
121 MpVDOP
122 )))
123 |PDOP| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
124 MpPDOP
125 )))
126 |Number of satellites used| |Field to note the amount of sattelites that where used for the GPS measurement in this measurement point.|Add|Integer|tblMeasurementPoints|(((
127 MpNumberOfSatellites
128 )))
129 |HRMS| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
130 MpHRMS
131 )))
132 |VRMS| |Precision value for the GPS coordinates.|Add|Float|tblMeasurementPoints|(((
133 MpVRMS
134 )))
135 |(((
136 Gps pole height (m)
137 )))| |(((
138 Field to fill in the height of the GPS pole
139 )))|Add|Float|tblMeasurementPoints|(((
140 MpGPSPoleHeight
141 )))
142 |(((
143 Antenna height (cm)
144 )))| |(((
145 Field to fill in the height of the antenna on the GPS machine
146 )))|Add|Float|tblMeasurementPoints|(((
147 MpAntennaHeight
148 )))
149 |Weather conditions| |(((
150 Field to fill in the weather conditions during the drilling process
151 )))|Add|Float|tblMeasurementPoints|MPWeatherConditions
152 |Ambient temperature (°C) | |(((
153 Outside temperature during the drilling process
154 )))|Add|Float|tblMeasurementPoints|(((
155 MpAmbientTemperature
156 )))
157 |(((
158 CO (ppm)
159 )))| |(((
160 Field to save the measurement of carbon monoxide in the layer
161 )))|Add|Float|tblLayers|LaCO
162 |(((
163 Oxygen ~(%)
164 )))| |(((
165 Field to save the measurement of oxygen in the layer
166 )))|Add|Float|tblLayers|(((
167 LaOxygenPercentage
168 )))
169 |(((
170 H2S (ppm)
171 )))| |Field to save the measurement of hydrogen sulfide in the layer|Add|Float|tblLayers|(((
172 LaH2S
173 )))
174 |(((
175 LEL ~(%)
176 )))| |(((
177 Field the save the lower explosive level measurement in the layer
178 )))|Add|Float|tblLayers|(((
179 LaLEL
180 )))
181 |Inspectie efficiency ~(%)| |The amount of soil in the layer that was able to be inspected properly for the purpose of asbestos research.|Add|Float|tblLayers|(((
182 LaInspectionEfficiencyPercentage
183 )))
184 |Mixing of soil| |(((
185 Field to denote the amount of mixing in this soil layer
186 )))|Add|Integer (codelist 291)|tblLayers|(((
187 LaDegreeOfSoilMixingCode
188 )))
189 |(((
190 CO (ppm)
191 )))| |(((
192 Field to save the measurement of carbon monoxide in the air sample
193 )))|Add|Float|tblObservations|METINGCODE 161
194 |Jar type| |Soil sample ring added to the codelist|Add codelist value| | |
195
196 **25-11-2022:**
197
198 (% class="table-hover" %)
199 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
200 **Change/Add/**
201
202 **Delete**
203 )))|**DB Type
204 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
205 |Status| |(((
206 This field is for planned measurement points, and can be used to determine the status (to be done, done, removed etc)
207 )))|Add|Lookup value (codelist 289)|tblMeasurementPoints|(((
208 MpStatusCode
209 )))
210 |(((
211 Penetrometer compaction strength (kg/cm2)
212 )))| |(((
213 This field is a numeric field for field tests to determine the compaction strength of the soil
214 )))|Add|numberfield|tblMeasurementPoints|MpPenetrometerCompaction
215 |(((
216 Accreditation number
217 )))| |(((
218 This field can be used to fill in the accreditation number of the fieldworker, which needs to be filled in by walloon customers
219 )))|Add|text field (30)|tblMeasurementPoints|(((
220 MpAccreditationNumber
221 )))
222 |Moisture Class Soil| |(((
223 This field is for giving moisture classes in soil, these are present in the NEN 6693 and also used for french research.
224 )))|Add|Lookup value (codelist 290)|tblLayers|(((
225 LaMoistureClass
226 )))
227 |Sediment Sump Length (cm)| |(((
228 Field to input the length within the tube that is used as a sand / silt catchment below the filter
229 )))|Add|numberfield|tblFilterTubes|FtSedimentSumpLength
230 |Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblMeasurementPoints|(((
231 MpTrialPitLength & MpTrialPitWidth
232 )))
233 |Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblLayers|(((
234 LaTrialPitLength & LaTrialPitWidth
235 )))
236 |Initial function| |(((
237 Field to input the function of the filtertube when it was installed
238 )))|Add|Lookup value (codelist 288)|tblFilterTubes|FtInitialFiltertubeFunction
239 |Weather conditions| |(((
240 Remarkable weather conditions can be noted here as part of a location inspection
241 )))|Add|String|tblSublocations|(((
242 SlCoverRatePostRemoval
243 )))
244 |Sampling procedure| |Field to fill in the used sampling procedure|Add|Lookup value (codelist 287)|tblWatersamples|WsSamplingProcedure
245 |Starttime & Endtime sampling|Already existed for airsamples, no as well for watersamples| |Change|Datetime|tblWatersamples|(((
246 WsStartSampleTime & WsPostSampleTime
247 )))
248 |Radioactive ionisation (cps)| |(((
249 Numberfield to input the cps (counts per second) of a meter that reacts to ionisation (like a geiger counter)
250 )))|Add|numberfield|tblJars|(((
251 JrIonisationCount
252 )))
253 |Sample water content ~(%)| |(((
254 Percentage field for sample humidity
255 )))|Add|numberfield|tblJars|JrHumidityPercentage
256 |(((
257 Volume weight dry Yd (Kn/M3)
258 )))| |(((
259 Geotechnical field for the dry weight of the sample, different unit than the other weight sample fields which are more simplistic
260 )))|Add|numberfield|tblJars|JrDryVolumeWeight
261 |Liquit limit water content ~(%)| |The liquid limit used within the attenbergs limits|Add|numberfield|tblJars|JrLiquidLimit
262 |Plasticity index ~(%)| |(((
263 Geotechnical field for the plasticity index
264 )))|Add|numberfield|tblJars|JrPlasticityIndex
265 |(((
266 Semi-Solid limit (water content %)
267 )))| |The semi-solid limit used within the attenbergs limits|Add|numberfield|tblJars|JrSemiSolidLimit
268 |(((
269 Plastic limit (water content %)
270 )))| |The plastic limit used within the attenbergs limits|Add|numberfield|tblJars|JrPlasticLimit
271 |(((
272 Undrained shear strength (kPa)
273 )))| |The shear strength of the soil|Add|numberfield|tblJars|JrUndrainedShearStrength
274 |Void ratio ~(%)| |The ratio of void (air) in the soil|Add|numberfield|tblJars|JrVoidRatio
275 |Saturation ~(%)| |The percentage of moisture saturation in the soil|Add|numberfield|tblJars|JrSaturationPercentage
276 |Soil sampes (several fields)|Multi edit turned on| |Change| |tblJars|Several
277 |Destination Type| |Field for destination type for the OVAM|Add|Lookup value (codelist 49)|tblProjects|PrDestinationType
278 |Groundwater vulnerability| |Field for groundwater vulnerability for the OVAM|Add|Lookup value (codelist 92)|tblProjects|PrGroundwaterVulnerability
279 |Percentage Fractrion >20mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaCourseFractionPercentage
280 |Weight fraction >20 mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaCourseFractionWeight
281 |Weight fraction <20 mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaFineFractionWeight
282 |Type plate material| |Asbestos fields now als on layer level|Add|Lookup value (281)|tblLayers|LaPlateMaterialTypeCode
283 |Number of pieces plate material| |Asbestos fields now als on layer level|Add|numberfield|tbLLayers|LaPlateMaterialPieces
284 |Weight plate material (g)| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaPlateMaterialWeight
285 |Special component gradation|Add codelist "A little (bit of)"| |Add Codelist value| | |
286 |Sand sorting codes|Add extra sand and gravel sorting codes| |Add Codelist value| | |
287 |Geological interpretation|All new belgium geological interpretation options added| |Add Codelist value| | |
288 |End prepump citeria|New prepump ending condition added| |Add Codelist value| | |
289 |Finishing Type|Type 'Asfalt' added| |Add Codelist value| | |
290 |Project Type|New French Project types added| |Add Codelist value| | |
291 |Colour Type|Colour 'Pink' added| |Add Codelist value| | |
292 |Use of location|Additional location uses added| |Add Codelist value| | |
293
294 **03-08-2022:**
295
296 (% class="table-hover" %)
297 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
298 **Change/Add/**
299
300 **Delete**
301 )))|**DB Type
302 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
303 |Special or invasive vegetation(1, 2, 3)| |Field to note invasive species found on the release location. New codelist with species from the dutch invasive species list added.|Add|Lookup value (codelist 285)|tblSublocations|(((
304 SlSpecialVegetationCode
305 )))
306 |Sieved material inspection hole| |Field to note the total amount of sieved material at the measurementpoint level of an asbestos inspection hole|Add|Float|tblMeasurementPoints|MpSievedMaterial
307 |Water depth (cm-gl)| |Field to describe the column of water above the waterbed, if chosen not to add a water layer as the first layer.|Add|Float|tblMeasurementPoints|MpWaterDepth
308 |Special component in layer (mass%)| |Can be used to note the total mass % of foreign (non-soil) material in a layer.|Add|Float|tblLayers|LaSpecialComponentPercent
309 |Suspected Asbestos pollution| |Field by which a fieldworker can remark if a layer is suspect of containing asbestos|Add|Lookup value (codelist 73)|tblLayers|LaSuspectedAsbestosCode
310 |Measurement point type|New codelist options added|Canister, Ambient air measurement added|Change|Lookup value (codelist 24)|tblMeasurementpoints|MpTypeCode
311 |Reference plane|New codelist options added|Sea level added|Change|Lookup value (codelist 15)|tblMeasurementpoints|MpReferencePointTypeCode
312 |Finishing Type|New codelist options added|Surface box plasic, Surface box stainless steel added|Change|Lookup value (codelist 32)|tblFinishings|FiTypeCode
313 |Horizon|New codelist options added|Unit R0, Unit R1, Unit R2 added|Change|Lookup value (codelist 109)|tblLayers|LaHorizonCode
314 |Soil / Rock Type|New codelist options added|Granodiorite added|Change|Lookup value (codelist 163 and 35)|tblLayers|LaRockTypeCode
315 |Special component type|New codelist options added|(((
316 Construction and demolition waste, Calcium nodules, calcium crusts, Stones >50MM added
317 )))|Change|Lookup value (codelist 11)|tblLayers|LaSc1TypeCode
318 |Drilling System|New codelist options added|Tubed edelman, tubed pulse drill, tubed percussion gouge added|Change|Lookup value (codelist 23)|tblLayers|LaDrillingSystemTypeCode
319 |Clarity|New codelist options added|None, Low, medium, high clarity codes added|Change|Lookup value (codelist 252)|tblWatersamples|LaClarityCode
320 |Stop prepumping|New codelist options added|1x volume of drilling well + parameters stabilisation added|Change|Lookup value (codelist 200)|tblWatersamples|WsPrepumpingEndedTypeCode
321 |Sampling method|New codelist options added|multi support active sampling|Change|Lookup value (codelist 259)|tblWatersamples|WsSamplingMethodCode
322 |Placed in serie|New codelist options added|New codelist: Unique, in paralel, in series added|Change|Lookup value (codelist 284)|WsPackagings|BoPlacedInSerie
323 |Air sample Type|New codelist options added|Impregnated filter added|Change|Lookup value (codelist 272)|WsPackagings|BoSampleTypeCode
324 |Field matrix|New codelist options added|Waterbed (solid part) added|Change|Lookup value (codelist 6)|WsAnalysisSamples|MatrixTypeCode
325
326 **27-01-2022:**
327
328 (% class="table-hover" %)
329 |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
330 **Change/Add/**
331
332 **Delete**
333 )))|**DB Type
334 (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
335 |Use of location| |To add the current use of the location to a measurement point|Add|Lookupvalue|tblMeasurementPoints|MpLocationUsageCode
336 |Type|New codelist optios added |-|Change|Lookupvalue|tblMeasurementPoint|MpType
337 |Interior location| |Yes / no field for if the sample is an interior location|Add|Lookupvalue|tblMeasurementPoints|MpIsIndoorsCode
338 |FlowTypesSurfaceWater| |Describes the flowing pattern of the surface water sampling location|Add|Lookupvalue|tblObservations|METINGCODE 148
339 |Location flow rate| |The flow rate of the sampling location|Add|Lookupvalue|tblObservations|METINGCODE 149
340 |Special conditions| |Remark field for special sampling conditions to print in report|Add|String|tblWatersamples|JrStreamlineGUID
341 |Pump type|Codelist used for several fields|New options added to codelist|Change|Lookupvalue|Multiple fields|Multiple fields
342 |Pump connection| |Field for the power connection of a pump|Add|LookupValue|tblObservations|METINGCODE 150
343 |Matrix| |Added codelist options|Change|Lookupvalue|tblWatersamples|WsMatrix
344 |Mesh size (mm)| |Field for the mesh size of a monitoring well filter|Add|Float|tblFiltertubes|FtMeshSize
345 |Type|Project level|New codelist options|Change|Lookupvalue|tblProjects|PrType
346 |Type|Finishing level|New codelist options|Change|Lookupvalue|tblFinishings|FiType
347 |Measurement duration| |Field for the duration of a series of a measurements, mostly used to estimate the time when a tube is dry|Add|Float|tblObservations|METINGCODE 154 (Series), METINGCODE 153 (Stable value)
348 |Pumped volume series| |Field for the total pumped volume during a single series|Add|Float|tblObservations|METINGCODE 152 (Series), METINGCODE 151 (Stable value)
349
350 **22-11-2021:**
351
352 |**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
353 | | | | | | | | | |
354 |Soil samples|Length core sampler|Lengte steekbuis (mm)|Length core sampler (mm)|The length of a core sampler may vary and defines volume| |Add|Integer|tblJars|JrLengthCoreSampler
355 |Measurement Point|Diameter|Diameter (mm)|Diameter (mm)|(% colspan="2" %)Information is available on layer level, but may sometimes be consistent over the entire measurement point|Add|Integer|tblMeasurementPoints|MpDiameter
356 |Air Samples packaging|Placed in serie|In serie geplaatst|Yes/no|Two packages for air samples can be placed in serie or not| |Add|Lookupvalue (Yes/No)|tblBottles|BoPlacedInSerie
357 |Water samples|Surrounding humidity|Omgevingsvochtigheid|Licht vochtig, Zeer vochtig, Vochtig op bodem, Vochtig op plaatsen|The circumstances when sampling| |Add|Codelist|(((
358 * tblObservations
359 * tblWatersampleMeasurements
360 )))|Metingcode: 147 / WsSurroundingHumidity
361
362 **18-10-2021:**
363
364 |=(% colspan="1" rowspan="1" %)(((
365 **Labeltext in English**
366 )))|=(% colspan="1" rowspan="1" %)(((
367 **Remarks**
368 )))|=(% colspan="1" rowspan="1" %)(((
369 **Definition and process how this field will be used and when it will be filled.**
370 )))|=(% colspan="1" rowspan="1" %)(((
371 **Change/Add/Delete**
372 )))|=(% colspan="1" rowspan="1" %)(((
373 **DB Type**
374 **(String (length) / Float / Lookupvalue / Integer / DateTime)**
375 )))|=(% colspan="1" rowspan="1" %)(((
376 **DBTable in dsFieldProject**
377 )))|=(% colspan="1" rowspan="1" %)(((
378 **DBFieldname in dsFieldProject**
379 )))
380 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblProjects|(% colspan="1" rowspan="1" %)PrStreamlineGUID
381 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpStreamlineGUID
382 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblWaterSample |(% colspan="1" rowspan="1" %)WsStreamlineGUID
383 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFiltertubes|(% colspan="1" rowspan="1" %)FtStreamlineGUID
384 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLayers|(% colspan="1" rowspan="1" %)LaStreamlineGUID
385 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrStreamlineGUID
386 |(% colspan="1" rowspan="1" %)PackagingStreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrPackagingStreamlineGUID
387 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFinishings|(% colspan="1" rowspan="1" %)FiStreamlineGUID
388 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoStreamlineGUID
389 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLocations|(% colspan="1" rowspan="1" %)LcStreamlineGUID
390 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblSublocations|(% colspan="1" rowspan="1" %)SlStreamlineGUID
391
392 **07-10-2021:**
393
394 |=(% colspan="1" rowspan="1" %)(((
395 **Screen to add the extra field**
396 )))|=(% colspan="1" rowspan="1" %)(((
397 **Labeltext in English**
398 )))|=(% colspan="1" rowspan="1" %)(((
399 **Labeltext in Dutch**
400 )))|=(% colspan="1" rowspan="1" %)(((
401 **Examples of values and how it should be printed in a report.**
402 )))|=(% colspan="1" rowspan="1" %)(((
403 **Definition and process how this field will be used and when it will be filled.**
404 )))|=(% colspan="1" rowspan="1" %)(((
405 **Change/Add/Delete**
406 )))|=(% colspan="1" rowspan="1" %)(((
407 **DB Type**
408 **(String (length) / Float / Lookupvalue / Integer / DateTime)**
409 )))|=(% colspan="1" rowspan="1" %)(((
410 **DBTable in dsFieldProject**
411 )))|=(% colspan="1" rowspan="1" %)(((
412 **DBFieldname in dsFieldProject**
413 )))
414 |(% colspan="1" rowspan="1" %)Measurement Points Details|(% colspan="1" rowspan="1" %)Sample Moisture|(% colspan="1" rowspan="1" %)Monstervochtigheid|(% colspan="1" rowspan="1" %)Dried out|(% colspan="1" rowspan="1" %)Explains humidity condition of measurment point|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpSampleHumidityCode
415 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Special conditions|(% colspan="1" rowspan="1" %)Bijzondere omstandigheden|(% colspan="1" rowspan="1" %)Normal, used standard protocol|(% colspan="1" rowspan="1" %)Description of deviation from protocol|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsSpecialConditions
416 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Field conditions|(% colspan="1" rowspan="1" %)Maaiveld omstandigheden|(% colspan="1" rowspan="1" %)Damp, easy to drill|(% colspan="1" rowspan="1" %)Description of field/location at time of sampling|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsFieldConditions
417 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - O2|(% colspan="1" rowspan="1" %)Kalibratie Zuurstof ~(%)|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 136 / WsCalibrationO2
418 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - CO2|(% colspan="1" rowspan="1" %)Kalibratie koolstofdioxine/CO2 (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 137 / WsCalibrationCO2
419 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Start-sampling time|(% colspan="1" rowspan="1" %)Tijdstip start bemonstering|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %)Time when the actual sampling has started|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsStartSampleTime
420 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling time|(% colspan="1" rowspan="1" %)Tijdstip einde monstername|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsPostSampleTime
421 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post- sampling O2|(% colspan="1" rowspan="1" %)Zuurstof einde monstername |(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 140 / WsPostSampleO2
422 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling CO2|(% colspan="1" rowspan="1" %)Koolstofdioxine/CO2 einde monstername  (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 141 / WsPostSampleCO2
423 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling air flow rate|(% colspan="1" rowspan="1" %)Debiet einde monstername |(% colspan="1" rowspan="1" %)0,3l/min|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 142 / WsPostSampleFlowRate
424 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling PID|(% colspan="1" rowspan="1" %)PID einde monstername |(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 143 / WsPostSamplePID
425 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling temperature|(% colspan="1" rowspan="1" %)Temperatuur einde monstername|(% colspan="1" rowspan="1" %)25C|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 144 / WsPostSampleTemperature
426 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air humidity|(% colspan="1" rowspan="1" %)Vochtigheid einde monstername|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 145 / WsPostSampleHumidity
427 |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air pressure|(% colspan="1" rowspan="1" %)Luchtdruk einde monstername|(% colspan="1" rowspan="1" %)25hPa|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 146 / WsPostSamplePressure
428 |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode
429 |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber
430