Wiki source code of TerraIndex ReleaseNotes
Version 3.3 by Roelof Zwaan on 2022/11/25 09:26
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | == Changes and updates: == | ||
| 2 | |||
| 3 | **25-11-2022:** | ||
| 4 | |||
| 5 | (% class="table-hover" %) | ||
| 6 | |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( | ||
| 7 | **Change/Add/** | ||
| 8 | |||
| 9 | **Delete** | ||
| 10 | )))|**DB Type | ||
| 11 | (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** | ||
| 12 | |Status| |((( | ||
| 13 | This field is for planned measurement points, and can be used to determine the status (to be done, done, removed etc) | ||
| 14 | )))|Add|Lookup value (codelist 289)|tblMeasurementPoints|((( | ||
| 15 | MpStatusCode | ||
| 16 | ))) | ||
| 17 | |((( | ||
| 18 | Penetrometer compaction strength (kg/cm2) | ||
| 19 | )))| |((( | ||
| 20 | This field is a numeric field for field tests to determine the compaction strength of the soil | ||
| 21 | )))|Add|numberfield|tblMeasurementPoints|MpPenetrometerCompaction | ||
| 22 | |((( | ||
| 23 | Accreditation number | ||
| 24 | )))| |((( | ||
| 25 | This field can be used to fill in the accreditation number of the fieldworker, which needs to be filled in by walloon customers | ||
| 26 | )))|Add|text field (30)|tblMeasurementPoints|((( | ||
| 27 | MpAccreditationNumber | ||
| 28 | ))) | ||
| 29 | |Moisture Class Soil| |((( | ||
| 30 | This field is for giving moisture classes in soil, these are present in the NEN 6693 and also used for french research. | ||
| 31 | )))|Add|Lookup value (codelist 290)|tblLayers|((( | ||
| 32 | LaMoistureClass | ||
| 33 | ))) | ||
| 34 | |Sediment Sump Length (cm)| |((( | ||
| 35 | Field to input the length within the tube that is used as a sand / silt catchment below the filter | ||
| 36 | )))|Add|numberfield|tblFilterTubes|FtSedimentSumpLength | ||
| 37 | |Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblMeasurementPoints|((( | ||
| 38 | MpTrialPitLength & MpTrialPitWidth | ||
| 39 | ))) | ||
| 40 | |Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblLayers|((( | ||
| 41 | LaTrialPitLength & LaTrialPitWidth | ||
| 42 | ))) | ||
| 43 | |Initial function| |((( | ||
| 44 | Field to input the function of the filtertube when it was installed | ||
| 45 | )))|Add|Lookup value (codelist 288)|tblFilterTubes|FtInitialFiltertubeFunction | ||
| 46 | |Weather conditions| |((( | ||
| 47 | Remarkable weather conditions can be noted here as part of a location inspection | ||
| 48 | )))|Add|String|tblSublocations|((( | ||
| 49 | SlCoverRatePostRemoval | ||
| 50 | ))) | ||
| 51 | |Sampling procedure| |Field to fill in the used sampling procedure|Add|Lookup value (codelist 287)|tblWatersamples|WsSamplingProcedure | ||
| 52 | |||
| 53 | |||
| 54 | **03-08-2022:** | ||
| 55 | |||
| 56 | (% class="table-hover" %) | ||
| 57 | |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( | ||
| 58 | **Change/Add/** | ||
| 59 | |||
| 60 | **Delete** | ||
| 61 | )))|**DB Type | ||
| 62 | (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** | ||
| 63 | |Special or invasive vegetation(1, 2, 3)| |Field to note invasive species found on the release location. New codelist with species from the dutch invasive species list added.|Add|Lookup value (codelist 285)|tblSublocations|((( | ||
| 64 | SlSpecialVegetationCode | ||
| 65 | ))) | ||
| 66 | |Sieved material inspection hole| |Field to note the total amount of sieved material at the measurementpoint level of an asbestos inspection hole|Add|Float|tblMeasurementPoints|MpSievedMaterial | ||
| 67 | |Water depth (cm-gl)| |Field to describe the column of water above the waterbed, if chosen not to add a water layer as the first layer.|Add|Float|tblMeasurementPoints|MpWaterDepth | ||
| 68 | |Special component in layer (mass%)| |Can be used to note the total mass % of foreign (non-soil) material in a layer.|Add|Float|tblLayers|LaSpecialComponentPercent | ||
| 69 | |Suspected Asbestos pollution| |Field by which a fieldworker can remark if a layer is suspect of containing asbestos|Add|Lookup value (codelist 73)|tblLayers|LaSuspectedAsbestosCode | ||
| 70 | |Measurement point type|New codelist options added|Canister, Ambient air measurement added|Change|Lookup value (codelist 24)|tblMeasurementpoints|MpTypeCode | ||
| 71 | |Reference plane|New codelist options added|Sea level added|Change|Lookup value (codelist 15)|tblMeasurementpoints|MpReferencePointTypeCode | ||
| 72 | |Finishing Type|New codelist options added|Surface box plasic, Surface box stainless steel added|Change|Lookup value (codelist 32)|tblFinishings|FiTypeCode | ||
| 73 | |Horizon|New codelist options added|Unit R0, Unit R1, Unit R2 added|Change|Lookup value (codelist 109)|tblLayers|LaHorizonCode | ||
| 74 | |Soil / Rock Type|New codelist options added|Granodiorite added|Change|Lookup value (codelist 163 and 35)|tblLayers|LaRockTypeCode | ||
| 75 | |Special component type|New codelist options added|((( | ||
| 76 | Construction and demolition waste, Calcium nodules, calcium crusts, Stones >50MM added | ||
| 77 | )))|Change|Lookup value (codelist 11)|tblLayers|LaSc1TypeCode | ||
| 78 | |Drilling System|New codelist options added|Tubed edelman, tubed pulse drill, tubed percussion gouge added|Change|Lookup value (codelist 23)|tblLayers|LaDrillingSystemTypeCode | ||
| 79 | |Clarity|New codelist options added|None, Low, medium, high clarity codes added|Change|Lookup value (codelist 252)|tblWatersamples|LaClarityCode | ||
| 80 | |Stop prepumping|New codelist options added|1x volume of drilling well + parameters stabilisation added|Change|Lookup value (codelist 200)|tblWatersamples|WsPrepumpingEndedTypeCode | ||
| 81 | |Sampling method|New codelist options added|multi support active sampling|Change|Lookup value (codelist 259)|tblWatersamples|WsSamplingMethodCode | ||
| 82 | |Placed in serie|New codelist options added|New codelist: Unique, in paralel, in series added|Change|Lookup value (codelist 284)|WsPackagings|BoPlacedInSerie | ||
| 83 | |Air sample Type|New codelist options added|Impregnated filter added|Change|Lookup value (codelist 272)|WsPackagings|BoSampleTypeCode | ||
| 84 | |Field matrix|New codelist options added|Waterbed (solid part) added|Change|Lookup value (codelist 6)|WsAnalysisSamples|MatrixTypeCode | ||
| 85 | |||
| 86 | **27-01-2022:** | ||
| 87 | |||
| 88 | (% class="table-hover" %) | ||
| 89 | |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( | ||
| 90 | **Change/Add/** | ||
| 91 | |||
| 92 | **Delete** | ||
| 93 | )))|**DB Type | ||
| 94 | (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** | ||
| 95 | |Use of location| |To add the current use of the location to a measurement point|Add|Lookupvalue|tblMeasurementPoints|MpLocationUsageCode | ||
| 96 | |Type|New codelist optios added |-|Change|Lookupvalue|tblMeasurementPoint|MpType | ||
| 97 | |Interior location| |Yes / no field for if the sample is an interior location|Add|Lookupvalue|tblMeasurementPoints|MpIsIndoorsCode | ||
| 98 | |FlowTypesSurfaceWater| |Describes the flowing pattern of the surface water sampling location|Add|Lookupvalue|tblObservations|METINGCODE 148 | ||
| 99 | |Location flow rate| |The flow rate of the sampling location|Add|Lookupvalue|tblObservations|METINGCODE 149 | ||
| 100 | |Special conditions| |Remark field for special sampling conditions to print in report|Add|String|tblWatersamples|JrStreamlineGUID | ||
| 101 | |Pump type|Codelist used for several fields|New options added to codelist|Change|Lookupvalue|Multiple fields|Multiple fields | ||
| 102 | |Pump connection| |Field for the power connection of a pump|Add|LookupValue|tblObservations|METINGCODE 150 | ||
| 103 | |Matrix| |Added codelist options|Change|Lookupvalue|tblWatersamples|WsMatrix | ||
| 104 | |Mesh size (mm)| |Field for the mesh size of a monitoring well filter|Add|Float|tblFiltertubes|FtMeshSize | ||
| 105 | |Type|Project level|New codelist options|Change|Lookupvalue|tblProjects|PrType | ||
| 106 | |Type|Finishing level|New codelist options|Change|Lookupvalue|tblFinishings|FiType | ||
| 107 | |Measurement duration| |Field for the duration of a series of a measurements, mostly used to estimate the time when a tube is dry|Add|Float|tblObservations|METINGCODE 154 (Series), METINGCODE 153 (Stable value) | ||
| 108 | |Pumped volume series| |Field for the total pumped volume during a single series|Add|Float|tblObservations|METINGCODE 152 (Series), METINGCODE 151 (Stable value) | ||
| 109 | |||
| 110 | **22-11-2021:** | ||
| 111 | |||
| 112 | |**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** | ||
| 113 | | | | | | | | | | | | ||
| 114 | |Soil samples|Length core sampler|Lengte steekbuis (mm)|Length core sampler (mm)|The length of a core sampler may vary and defines volume| |Add|Integer|tblJars|JrLengthCoreSampler | ||
| 115 | |Measurement Point|Diameter|Diameter (mm)|Diameter (mm)|(% colspan="2" %)Information is available on layer level, but may sometimes be consistent over the entire measurement point|Add|Integer|tblMeasurementPoints|MpDiameter | ||
| 116 | |Air Samples packaging|Placed in serie|In serie geplaatst|Yes/no|Two packages for air samples can be placed in serie or not| |Add|Lookupvalue (Yes/No)|tblBottles|BoPlacedInSerie | ||
| 117 | |Water samples|Surrounding humidity|Omgevingsvochtigheid|Licht vochtig, Zeer vochtig, Vochtig op bodem, Vochtig op plaatsen|The circumstances when sampling| |Add|Codelist|((( | ||
| 118 | * tblObservations | ||
| 119 | * tblWatersampleMeasurements | ||
| 120 | )))|Metingcode: 147 / WsSurroundingHumidity | ||
| 121 | |||
| 122 | **18-10-2021:** | ||
| 123 | |||
| 124 | |=(% colspan="1" rowspan="1" %)((( | ||
| 125 | **Labeltext in English** | ||
| 126 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 127 | **Remarks** | ||
| 128 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 129 | **Definition and process how this field will be used and when it will be filled.** | ||
| 130 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 131 | **Change/Add/Delete** | ||
| 132 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 133 | **DB Type** | ||
| 134 | **(String (length) / Float / Lookupvalue / Integer / DateTime)** | ||
| 135 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 136 | **DBTable in dsFieldProject** | ||
| 137 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 138 | **DBFieldname in dsFieldProject** | ||
| 139 | ))) | ||
| 140 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblProjects|(% colspan="1" rowspan="1" %)PrStreamlineGUID | ||
| 141 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpStreamlineGUID | ||
| 142 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblWaterSample |(% colspan="1" rowspan="1" %)WsStreamlineGUID | ||
| 143 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFiltertubes|(% colspan="1" rowspan="1" %)FtStreamlineGUID | ||
| 144 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLayers|(% colspan="1" rowspan="1" %)LaStreamlineGUID | ||
| 145 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrStreamlineGUID | ||
| 146 | |(% colspan="1" rowspan="1" %)PackagingStreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrPackagingStreamlineGUID | ||
| 147 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFinishings|(% colspan="1" rowspan="1" %)FiStreamlineGUID | ||
| 148 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoStreamlineGUID | ||
| 149 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLocations|(% colspan="1" rowspan="1" %)LcStreamlineGUID | ||
| 150 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblSublocations|(% colspan="1" rowspan="1" %)SlStreamlineGUID | ||
| 151 | |||
| 152 | **07-10-2021:** | ||
| 153 | |||
| 154 | |=(% colspan="1" rowspan="1" %)((( | ||
| 155 | **Screen to add the extra field** | ||
| 156 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 157 | **Labeltext in English** | ||
| 158 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 159 | **Labeltext in Dutch** | ||
| 160 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 161 | **Examples of values and how it should be printed in a report.** | ||
| 162 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 163 | **Definition and process how this field will be used and when it will be filled.** | ||
| 164 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 165 | **Change/Add/Delete** | ||
| 166 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 167 | **DB Type** | ||
| 168 | **(String (length) / Float / Lookupvalue / Integer / DateTime)** | ||
| 169 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 170 | **DBTable in dsFieldProject** | ||
| 171 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 172 | **DBFieldname in dsFieldProject** | ||
| 173 | ))) | ||
| 174 | |(% colspan="1" rowspan="1" %)Measurement Points Details|(% colspan="1" rowspan="1" %)Sample Moisture|(% colspan="1" rowspan="1" %)Monstervochtigheid|(% colspan="1" rowspan="1" %)Dried out|(% colspan="1" rowspan="1" %)Explains humidity condition of measurment point|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpSampleHumidityCode | ||
| 175 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Special conditions|(% colspan="1" rowspan="1" %)Bijzondere omstandigheden|(% colspan="1" rowspan="1" %)Normal, used standard protocol|(% colspan="1" rowspan="1" %)Description of deviation from protocol|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsSpecialConditions | ||
| 176 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Field conditions|(% colspan="1" rowspan="1" %)Maaiveld omstandigheden|(% colspan="1" rowspan="1" %)Damp, easy to drill|(% colspan="1" rowspan="1" %)Description of field/location at time of sampling|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsFieldConditions | ||
| 177 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - O2|(% colspan="1" rowspan="1" %)Kalibratie Zuurstof ~(%)|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 136 / WsCalibrationO2 | ||
| 178 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - CO2|(% colspan="1" rowspan="1" %)Kalibratie koolstofdioxine/CO2 (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 137 / WsCalibrationCO2 | ||
| 179 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Start-sampling time|(% colspan="1" rowspan="1" %)Tijdstip start bemonstering|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %)Time when the actual sampling has started|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsStartSampleTime | ||
| 180 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling time|(% colspan="1" rowspan="1" %)Tijdstip einde monstername|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsPostSampleTime | ||
| 181 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post- sampling O2|(% colspan="1" rowspan="1" %)Zuurstof einde monstername |(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 140 / WsPostSampleO2 | ||
| 182 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling CO2|(% colspan="1" rowspan="1" %)Koolstofdioxine/CO2 einde monstername (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 141 / WsPostSampleCO2 | ||
| 183 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling air flow rate|(% colspan="1" rowspan="1" %)Debiet einde monstername |(% colspan="1" rowspan="1" %)0,3l/min|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 142 / WsPostSampleFlowRate | ||
| 184 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling PID|(% colspan="1" rowspan="1" %)PID einde monstername |(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 143 / WsPostSamplePID | ||
| 185 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling temperature|(% colspan="1" rowspan="1" %)Temperatuur einde monstername|(% colspan="1" rowspan="1" %)25C|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 144 / WsPostSampleTemperature | ||
| 186 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air humidity|(% colspan="1" rowspan="1" %)Vochtigheid einde monstername|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 145 / WsPostSampleHumidity | ||
| 187 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air pressure|(% colspan="1" rowspan="1" %)Luchtdruk einde monstername|(% colspan="1" rowspan="1" %)25hPa|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 146 / WsPostSamplePressure | ||
| 188 | |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode | ||
| 189 | |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber | ||
| 190 | |||
| 191 |