From version < 4.1 >
edited by Roelof Zwaan
on 2023/04/12 11:40
To version < 8.1
edited by Roelof Zwaan
on 2023/07/24 15:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,110 @@
1 1  == Changes and updates: ==
2 2  
3 +**26-07-2023**
4 +
5 +(% class="table-hover" %)
6 +|**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
7 +**Change/Add/**
8 +
9 +**Delete**
10 +)))|**DB Type
11 +(String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
12 +|Name inspector| |Field where the name of the fieldworker that performed the field inspection can be selected.|Add|String|tblSublocations|SlNameInspector
13 +|Coverage removed?| |Yes/No field to indicate whether or not any vegetation was removed in order to perform a field inspection.|Add|Lookupvalue (73)|tblSublocations|(((
14 +SlCoverageRemoved
15 +)))
16 +|(((
17 +Density (ton/m3)
18 +)))| |Field where the name of the fieldworker that performed the field inspection can be selected.|Add|Float|tblLayers|LaDensity
19 +|pH-value| |Field to enter the measured Ph value of this soil layer. Often used to map out contamination from drug waste.|Add|Float|tblLayers|LaPhValue
20 +|CH4 (ppm)| |The CH4 (methane) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 162
21 +|(((
22 +CO (ppm)
23 +)))| |The CO (Carbonmonoxide) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 161
24 +|CH4 (ppm) Series value| |The CH4 (methane) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 162
25 +|(((
26 +CO (ppm) Series value
27 +)))| |The CO (Carbonmonoxide) value measured during the sampling of a soil air or ambient air sample. Measured in parts per million (ppm).|Add|Float|tblObservations|METINGCODE 161
28 +|(((
29 +Reference of the Flow-measurement device
30 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|WsDebitReference
31 +|(((
32 +Reference of the explosimeter
33 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
34 +WsExplosimeterReference
35 +)))
36 +|(((
37 +Reference of the barometer
38 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
39 +WsBarometerReference
40 +)))
41 +|(((
42 +Reference of the O2/ Co2 sensor
43 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
44 +WsOxygenSensorReference
45 +)))
46 +|(((
47 +Reference PID-instrument
48 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
49 +WsPIDMeterReference
50 +)))
51 +|(((
52 +Reference of the hygrometer
53 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
54 +WsHygrometerReference
55 +)))
56 +|(((
57 +Reference of the pump
58 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
59 +WsPumpReference
60 +)))
61 +|(((
62 +Drilling fluid used
63 +)))| |If a fluid was used to aid the drilling, that fluid can be specified in this field. Required by Spanish ENAC standards.|Add|Lookupvalue (293)|tblMeasurementPoints|(((
64 +MpDrillingFluid
65 +)))
66 +|(((
67 +Reference PID-instrument
68 +)))| |The referencecode of the used PID-instrument.|Add|String|tblMeasurementPoints|(((
69 +MpPIDReference
70 +)))
71 +|(((
72 +Gravel grain size from (mm)
73 +)))| |The median of the type of gravel that has been used in the finishings of a filtertube.|Add|Float|tblFinishings|(((
74 +FiGravelSizeFrom
75 +)))
76 +|Gravel grain size to (mm)| |The median of the type of gravel that has been used in the finishings of a filtertube.|Add|Float|tblFinishings|(((
77 +FiGravelSizeTo
78 +)))
79 +|(((
80 +Type of rod grease used
81 +)))| |The type of grease used to connect different parts of the filtertubes.|Add|Lookupvalue (295)|tblFilterTubes|(((
82 +FtRodGrease
83 +)))
84 +|(((
85 +Reference of the purging water filter
86 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
87 +WsFilterReference
88 +)))
89 +|(((
90 +Reference of the multi-parameter sensor
91 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
92 +WsMultiParameterSensorReference
93 +)))
94 +|(((
95 +Reference of the waterlevel sensor
96 +)))| |The reference number of the device used in this sampling of soil air.|Add|String|tblWatersamples|(((
97 +WsGroundwaterSensorReference
98 +)))
99 +|(((
100 +n/a
101 +)))| |Technical field for the exchange of field samples (air / water)|Add|GUID|tblWatersamples|WsFieldSampleGuid
102 +|Reason| |Field t indicate the reason for starting the research|Add|Lookupvalue (294)|tblSummaryConclusion|(((
103 +SmReasonCode
104 +)))
105 +| | | | | | |
106 +
107 +
3 3  **05-04-2023**
4 4  
5 5  (% class="table-hover" %)
... ... @@ -41,8 +41,52 @@
41 41  )))|Add|Float|tblMeasurementPoints|(((
42 42  MpAntennaHeight
43 43  )))
44 -| | | | | | |MPWeatherConditions
45 -| | | | | | |
149 +|Weather conditions| |(((
150 +Field to fill in the weather conditions during the drilling process
151 +)))|Add|Float|tblMeasurementPoints|MPWeatherConditions
152 +|Ambient temperature (°C) | |(((
153 +Outside temperature during the drilling process
154 +)))|Add|Float|tblMeasurementPoints|(((
155 +MpAmbientTemperature
156 +)))
157 +|(((
158 +CO (ppm)
159 +)))| |(((
160 +Field to save the measurement of carbon monoxide in the layer
161 +)))|Add|Float|tblLayers|LaCO
162 +|(((
163 +Oxygen ~(%)
164 +)))| |(((
165 +Field to save the measurement of oxygen in the layer
166 +)))|Add|Float|tblLayers|(((
167 +LaOxygenPercentage
168 +)))
169 +|(((
170 +H2S (ppm)
171 +)))| |Field to save the measurement of hydrogen sulfide in the layer|Add|Float|tblLayers|(((
172 +LaH2S
173 +)))
174 +|(((
175 +LEL ~(%)
176 +)))| |(((
177 +Field the save the lower explosive level measurement in the layer
178 +)))|Add|Float|tblLayers|(((
179 +LaLEL
180 +)))
181 +|Inspectie efficiency ~(%)| |The amount of soil in the layer that was able to be inspected properly for the purpose of asbestos research.|Add|Float|tblLayers|(((
182 +LaInspectionEfficiencyPercentage
183 +)))
184 +|Mixing of soil| |(((
185 +Field to denote the amount of mixing in this soil layer
186 +)))|Add|Integer (codelist 291)|tblLayers|(((
187 +LaDegreeOfSoilMixingCode
188 +)))
189 +|(((
190 +CO (ppm)
191 +)))| |(((
192 +Field to save the measurement of carbon monoxide in the air sample
193 +)))|Add|Float|tblObservations|METINGCODE 161
194 +|Jar type| |Soil sample ring added to the codelist|Add codelist value| | |
46 46  
47 47  **25-11-2022:**
48 48  
TerraIndex