Changes for page TerraIndex ReleaseNotes
Last modified by Roelof Zwaan on 2023/07/24 15:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.Ro binHuisman1 +XWiki.RoelofZwaan - Content
-
... ... @@ -1,5 +1,155 @@ 1 1 == Changes and updates: == 2 2 3 +**25-11-2022:** 4 + 5 +(% class="table-hover" %) 6 +|**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( 7 +**Change/Add/** 8 + 9 +**Delete** 10 +)))|**DB Type 11 +(String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** 12 +|Status| |((( 13 +This field is for planned measurement points, and can be used to determine the status (to be done, done, removed etc) 14 +)))|Add|Lookup value (codelist 289)|tblMeasurementPoints|((( 15 +MpStatusCode 16 +))) 17 +|((( 18 +Penetrometer compaction strength (kg/cm2) 19 +)))| |((( 20 +This field is a numeric field for field tests to determine the compaction strength of the soil 21 +)))|Add|numberfield|tblMeasurementPoints|MpPenetrometerCompaction 22 +|((( 23 +Accreditation number 24 +)))| |((( 25 +This field can be used to fill in the accreditation number of the fieldworker, which needs to be filled in by walloon customers 26 +)))|Add|text field (30)|tblMeasurementPoints|((( 27 +MpAccreditationNumber 28 +))) 29 +|Moisture Class Soil| |((( 30 +This field is for giving moisture classes in soil, these are present in the NEN 6693 and also used for french research. 31 +)))|Add|Lookup value (codelist 290)|tblLayers|((( 32 +LaMoistureClass 33 +))) 34 +|Sediment Sump Length (cm)| |((( 35 +Field to input the length within the tube that is used as a sand / silt catchment below the filter 36 +)))|Add|numberfield|tblFilterTubes|FtSedimentSumpLength 37 +|Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblMeasurementPoints|((( 38 +MpTrialPitLength & MpTrialPitWidth 39 +))) 40 +|Length / Width|Multi edit turned on in grid vierw| |Change|numberfield|tblLayers|((( 41 +LaTrialPitLength & LaTrialPitWidth 42 +))) 43 +|Initial function| |((( 44 +Field to input the function of the filtertube when it was installed 45 +)))|Add|Lookup value (codelist 288)|tblFilterTubes|FtInitialFiltertubeFunction 46 +|Weather conditions| |((( 47 +Remarkable weather conditions can be noted here as part of a location inspection 48 +)))|Add|String|tblSublocations|((( 49 +SlCoverRatePostRemoval 50 +))) 51 +|Sampling procedure| |Field to fill in the used sampling procedure|Add|Lookup value (codelist 287)|tblWatersamples|WsSamplingProcedure 52 +|Starttime & Endtime sampling|Already existed for airsamples, no as well for watersamples| |Change|Datetime|tblWatersamples|((( 53 +WsStartSampleTime & WsPostSampleTime 54 +))) 55 +|Radioactive ionisation (cps)| |((( 56 +Numberfield to input the cps (counts per second) of a meter that reacts to ionisation (like a geiger counter) 57 +)))|Add|numberfield|tblJars|((( 58 +JrIonisationCount 59 +))) 60 +|Sample water content ~(%)| |((( 61 +Percentage field for sample humidity 62 +)))|Add|numberfield|tblJars|JrHumidityPercentage 63 +|((( 64 +Volume weight dry Yd (Kn/M3) 65 +)))| |((( 66 +Geotechnical field for the dry weight of the sample, different unit than the other weight sample fields which are more simplistic 67 +)))|Add|numberfield|tblJars|JrDryVolumeWeight 68 +|Liquit limit water content ~(%)| |The liquid limit used within the attenbergs limits|Add|numberfield|tblJars|JrLiquidLimit 69 +|Plasticity index ~(%)| |((( 70 +Geotechnical field for the plasticity index 71 +)))|Add|numberfield|tblJars|JrPlasticityIndex 72 +|((( 73 +Semi-Solid limit (water content %) 74 +)))| |The semi-solid limit used within the attenbergs limits|Add|numberfield|tblJars|JrSemiSolidLimit 75 +|((( 76 +Plastic limit (water content %) 77 +)))| |The plastic limit used within the attenbergs limits|Add|numberfield|tblJars|JrPlasticLimit 78 +|((( 79 +Undrained shear strength (kPa) 80 +)))| |The shear strength of the soil|Add|numberfield|tblJars|JrUndrainedShearStrength 81 +|Void ratio ~(%)| |The ratio of void (air) in the soil|Add|numberfield|tblJars|JrVoidRatio 82 +|Saturation ~(%)| |The percentage of moisture saturation in the soil|Add|numberfield|tblJars|JrSaturationPercentage 83 +|Soil sampes (several fields)|Multi edit turned on| |Change| |tblJars|Several 84 +|Destination Type| |Field for destination type for the OVAM|Add|Lookup value (codelist 49)|tblProjects|PrDestinationType 85 +|Groundwater vulnerability| |Field for groundwater vulnerability for the OVAM|Add|Lookup value (codelist 92)|tblProjects|PrGroundwaterVulnerability 86 +|Percentage Fractrion >20mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaCourseFractionPercentage 87 +|Weight fraction >20 mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaCourseFractionWeight 88 +|Weight fraction <20 mm| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaFineFractionWeight 89 +|Type plate material| |Asbestos fields now als on layer level|Add|Lookup value (281)|tblLayers|LaPlateMaterialTypeCode 90 +|Number of pieces plate material| |Asbestos fields now als on layer level|Add|numberfield|tbLLayers|LaPlateMaterialPieces 91 +|Weight plate material (g)| |Asbestos fields now als on layer level|Add|numberfield|tblLayers|LaPlateMaterialWeight 92 +|Special component gradation|Add codelist "A little (bit of)"| |Change codelist value| | | 93 +|Sand sorting codes|Add extra sand and gravel sorting codes| |Change codelist value| | | 94 +| | | | | | | 95 + 96 + 97 +**03-08-2022:** 98 + 99 +(% class="table-hover" %) 100 +|**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( 101 +**Change/Add/** 102 + 103 +**Delete** 104 +)))|**DB Type 105 +(String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** 106 +|Special or invasive vegetation(1, 2, 3)| |Field to note invasive species found on the release location. New codelist with species from the dutch invasive species list added.|Add|Lookup value (codelist 285)|tblSublocations|((( 107 +SlSpecialVegetationCode 108 +))) 109 +|Sieved material inspection hole| |Field to note the total amount of sieved material at the measurementpoint level of an asbestos inspection hole|Add|Float|tblMeasurementPoints|MpSievedMaterial 110 +|Water depth (cm-gl)| |Field to describe the column of water above the waterbed, if chosen not to add a water layer as the first layer.|Add|Float|tblMeasurementPoints|MpWaterDepth 111 +|Special component in layer (mass%)| |Can be used to note the total mass % of foreign (non-soil) material in a layer.|Add|Float|tblLayers|LaSpecialComponentPercent 112 +|Suspected Asbestos pollution| |Field by which a fieldworker can remark if a layer is suspect of containing asbestos|Add|Lookup value (codelist 73)|tblLayers|LaSuspectedAsbestosCode 113 +|Measurement point type|New codelist options added|Canister, Ambient air measurement added|Change|Lookup value (codelist 24)|tblMeasurementpoints|MpTypeCode 114 +|Reference plane|New codelist options added|Sea level added|Change|Lookup value (codelist 15)|tblMeasurementpoints|MpReferencePointTypeCode 115 +|Finishing Type|New codelist options added|Surface box plasic, Surface box stainless steel added|Change|Lookup value (codelist 32)|tblFinishings|FiTypeCode 116 +|Horizon|New codelist options added|Unit R0, Unit R1, Unit R2 added|Change|Lookup value (codelist 109)|tblLayers|LaHorizonCode 117 +|Soil / Rock Type|New codelist options added|Granodiorite added|Change|Lookup value (codelist 163 and 35)|tblLayers|LaRockTypeCode 118 +|Special component type|New codelist options added|((( 119 +Construction and demolition waste, Calcium nodules, calcium crusts, Stones >50MM added 120 +)))|Change|Lookup value (codelist 11)|tblLayers|LaSc1TypeCode 121 +|Drilling System|New codelist options added|Tubed edelman, tubed pulse drill, tubed percussion gouge added|Change|Lookup value (codelist 23)|tblLayers|LaDrillingSystemTypeCode 122 +|Clarity|New codelist options added|None, Low, medium, high clarity codes added|Change|Lookup value (codelist 252)|tblWatersamples|LaClarityCode 123 +|Stop prepumping|New codelist options added|1x volume of drilling well + parameters stabilisation added|Change|Lookup value (codelist 200)|tblWatersamples|WsPrepumpingEndedTypeCode 124 +|Sampling method|New codelist options added|multi support active sampling|Change|Lookup value (codelist 259)|tblWatersamples|WsSamplingMethodCode 125 +|Placed in serie|New codelist options added|New codelist: Unique, in paralel, in series added|Change|Lookup value (codelist 284)|WsPackagings|BoPlacedInSerie 126 +|Air sample Type|New codelist options added|Impregnated filter added|Change|Lookup value (codelist 272)|WsPackagings|BoSampleTypeCode 127 +|Field matrix|New codelist options added|Waterbed (solid part) added|Change|Lookup value (codelist 6)|WsAnalysisSamples|MatrixTypeCode 128 + 129 +**27-01-2022:** 130 + 131 +(% class="table-hover" %) 132 +|**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( 133 +**Change/Add/** 134 + 135 +**Delete** 136 +)))|**DB Type 137 +(String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** 138 +|Use of location| |To add the current use of the location to a measurement point|Add|Lookupvalue|tblMeasurementPoints|MpLocationUsageCode 139 +|Type|New codelist optios added |-|Change|Lookupvalue|tblMeasurementPoint|MpType 140 +|Interior location| |Yes / no field for if the sample is an interior location|Add|Lookupvalue|tblMeasurementPoints|MpIsIndoorsCode 141 +|FlowTypesSurfaceWater| |Describes the flowing pattern of the surface water sampling location|Add|Lookupvalue|tblObservations|METINGCODE 148 142 +|Location flow rate| |The flow rate of the sampling location|Add|Lookupvalue|tblObservations|METINGCODE 149 143 +|Special conditions| |Remark field for special sampling conditions to print in report|Add|String|tblWatersamples|JrStreamlineGUID 144 +|Pump type|Codelist used for several fields|New options added to codelist|Change|Lookupvalue|Multiple fields|Multiple fields 145 +|Pump connection| |Field for the power connection of a pump|Add|LookupValue|tblObservations|METINGCODE 150 146 +|Matrix| |Added codelist options|Change|Lookupvalue|tblWatersamples|WsMatrix 147 +|Mesh size (mm)| |Field for the mesh size of a monitoring well filter|Add|Float|tblFiltertubes|FtMeshSize 148 +|Type|Project level|New codelist options|Change|Lookupvalue|tblProjects|PrType 149 +|Type|Finishing level|New codelist options|Change|Lookupvalue|tblFinishings|FiType 150 +|Measurement duration| |Field for the duration of a series of a measurements, mostly used to estimate the time when a tube is dry|Add|Float|tblObservations|METINGCODE 154 (Series), METINGCODE 153 (Stable value) 151 +|Pumped volume series| |Field for the total pumped volume during a single series|Add|Float|tblObservations|METINGCODE 152 (Series), METINGCODE 151 (Stable value) 152 + 3 3 **22-11-2021:** 4 4 5 5 |**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** ... ... @@ -41,3 +41,44 @@ 41 41 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoStreamlineGUID 42 42 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLocations|(% colspan="1" rowspan="1" %)LcStreamlineGUID 43 43 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblSublocations|(% colspan="1" rowspan="1" %)SlStreamlineGUID 194 + 195 +**07-10-2021:** 196 + 197 +|=(% colspan="1" rowspan="1" %)((( 198 +**Screen to add the extra field** 199 +)))|=(% colspan="1" rowspan="1" %)((( 200 +**Labeltext in English** 201 +)))|=(% colspan="1" rowspan="1" %)((( 202 +**Labeltext in Dutch** 203 +)))|=(% colspan="1" rowspan="1" %)((( 204 +**Examples of values and how it should be printed in a report.** 205 +)))|=(% colspan="1" rowspan="1" %)((( 206 +**Definition and process how this field will be used and when it will be filled.** 207 +)))|=(% colspan="1" rowspan="1" %)((( 208 +**Change/Add/Delete** 209 +)))|=(% colspan="1" rowspan="1" %)((( 210 +**DB Type** 211 +**(String (length) / Float / Lookupvalue / Integer / DateTime)** 212 +)))|=(% colspan="1" rowspan="1" %)((( 213 +**DBTable in dsFieldProject** 214 +)))|=(% colspan="1" rowspan="1" %)((( 215 +**DBFieldname in dsFieldProject** 216 +))) 217 +|(% colspan="1" rowspan="1" %)Measurement Points Details|(% colspan="1" rowspan="1" %)Sample Moisture|(% colspan="1" rowspan="1" %)Monstervochtigheid|(% colspan="1" rowspan="1" %)Dried out|(% colspan="1" rowspan="1" %)Explains humidity condition of measurment point|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpSampleHumidityCode 218 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Special conditions|(% colspan="1" rowspan="1" %)Bijzondere omstandigheden|(% colspan="1" rowspan="1" %)Normal, used standard protocol|(% colspan="1" rowspan="1" %)Description of deviation from protocol|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsSpecialConditions 219 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Field conditions|(% colspan="1" rowspan="1" %)Maaiveld omstandigheden|(% colspan="1" rowspan="1" %)Damp, easy to drill|(% colspan="1" rowspan="1" %)Description of field/location at time of sampling|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsFieldConditions 220 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - O2|(% colspan="1" rowspan="1" %)Kalibratie Zuurstof ~(%)|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 136 / WsCalibrationO2 221 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - CO2|(% colspan="1" rowspan="1" %)Kalibratie koolstofdioxine/CO2 (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 137 / WsCalibrationCO2 222 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Start-sampling time|(% colspan="1" rowspan="1" %)Tijdstip start bemonstering|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %)Time when the actual sampling has started|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsStartSampleTime 223 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling time|(% colspan="1" rowspan="1" %)Tijdstip einde monstername|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsPostSampleTime 224 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post- sampling O2|(% colspan="1" rowspan="1" %)Zuurstof einde monstername |(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 140 / WsPostSampleO2 225 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling CO2|(% colspan="1" rowspan="1" %)Koolstofdioxine/CO2 einde monstername (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 141 / WsPostSampleCO2 226 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling air flow rate|(% colspan="1" rowspan="1" %)Debiet einde monstername |(% colspan="1" rowspan="1" %)0,3l/min|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 142 / WsPostSampleFlowRate 227 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling PID|(% colspan="1" rowspan="1" %)PID einde monstername |(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 143 / WsPostSamplePID 228 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling temperature|(% colspan="1" rowspan="1" %)Temperatuur einde monstername|(% colspan="1" rowspan="1" %)25C|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 144 / WsPostSampleTemperature 229 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air humidity|(% colspan="1" rowspan="1" %)Vochtigheid einde monstername|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 145 / WsPostSampleHumidity 230 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air pressure|(% colspan="1" rowspan="1" %)Luchtdruk einde monstername|(% colspan="1" rowspan="1" %)25hPa|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 146 / WsPostSamplePressure 231 +|(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode 232 +|(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber 233 + 234 +