From version 1.1 >
edited by Robin Huisman
on 2021/11/29 15:16
To version < 2.4 >
edited by Roelof Zwaan
on 2022/08/04 09:15
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.RobinHuisman
1 +XWiki.RoelofZwaan
Content
... ... @@ -1,5 +1,61 @@
1 1  == Changes and updates: ==
2 2  
3 +**03-08-2022:**
4 +
5 +(% class="table-hover" %)
6 +|**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
7 +**Change/Add/**
8 +
9 +**Delete**
10 +)))|**DB Type
11 +(String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
12 +|Special or invasive vegetation(1, 2, 3)| |Field to note invasive species found on the release location. New codelist with species from the dutch invasive species list added.|Add|Lookup value (codelist 285)|tblSublocations|(((
13 +SlVegetationCode
14 +)))
15 +|Sieved material inspection hole| |Field to note the total amount of sieved material at the measurementpoint level of an asbestos inspection hole|Add|Float|tblMeasurementPoints|MpSievedMaterial
16 +|Water depth (cm-gl)| |Field to describe the column of water above the waterbed, if chosen not to add a water layer as the first layer.|Add|Float|tblMeasurementPoints|MpWaterDepth
17 +|Special component in layer (mass%)| |Can be used to note the total mass % of foreign (non-soil) material in a layer.|Add|Float|tblLayers|LaSpecialComponentPercent
18 +|Suspected Asbestos pollution| |Field by which a fieldworker can remark if a layer is suspect of containing asbestos|Add|Lookup value (codelist 73)|tblLayers|LaSuspectedAsbestosCode
19 +|Measurement point type|New codelist options added|Canister, Ambient air measurement added|Change|Lookup value (codelist 24)|tblMeasurementpoints|MpTypeCode
20 +|Reference plane|New codelist options added|Sea level added|Change|Lookup value (codelist 15)|tblMeasurementpoints|MpReferencePointTypeCode
21 +|Finishing Type|New codelist options added| |Change|Lookup value (codelist 32)|tblFinishings|FiTypeCode
22 +|Horizon|New codelist options added| |Change|Lookup value (codelist 109)|tblLayers|LaHorizonCode
23 +|Soil / Rock Type|New codelist options added| |Change|Lookup value (codelist 163 and 35)|tblLayers|LaRockTypeCode
24 +|Special component type|New codelist options added| |Change|Lookup value (codelist 11)|tblLayers|LaSc1TypeCode
25 +|Drilling System|New codelist options added| |Change|Lookup value (codelist 23)|tblLayers|LaDrillingSystemTypeCode
26 +|Clarity|New codelist options added| |Change|Lookup value (codelist 252)|tblWatersamples|LaClarityCode
27 +|Stop prepumping|New codelist options added| |Change|Lookup value (codelist 200)|tblWatersamples|WsPrepumpingEndedTypeCode
28 +|Sampling method|New codelist options added| |Change|Lookup value (codelist 259)|tblWatersamples|WsSamplingMethodCode
29 +|Placed in serie|New codelist options added| |Change|Lookup value (codelist 284)|WsPackagings|BoPlacedInSerie
30 +|Air sample Type|New codelist options added| |Change|Lookup value (codelist 272)|WsPackagings|BoSampleTypeCode
31 +|Field matrix|New codelist options added| |Change|Lookup value (codelist 6)|WsAnalysisSamples|MatrixTypeCode
32 +
33 +
34 +**27-01-2022:**
35 +
36 +(% class="table-hover" %)
37 +|**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|(((
38 +**Change/Add/**
39 +
40 +**Delete**
41 +)))|**DB Type
42 +(String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
43 +|Use of location| |To add the current use of the location to a measurement point|Add|Lookupvalue|tblMeasurementPoints|MpLocationUsageCode
44 +|Type|New codelist optios added |-|Change|Lookupvalue|tblMeasurementPoint|MpType
45 +|Interior location| |Yes / no field for if the sample is an interior location|Add|Lookupvalue|tblMeasurementPoints|MpIsIndoorsCode
46 +|FlowTypesSurfaceWater| |Describes the flowing pattern of the surface water sampling location|Add|Lookupvalue|tblObservations|METINGCODE 148
47 +|Location flow rate| |The flow rate of the sampling location|Add|Lookupvalue|tblObservations|METINGCODE 149
48 +|Special conditions| |Remark field for special sampling conditions to print in report|Add|String|tblWatersamples|JrStreamlineGUID
49 +|Pump type|Codelist used for several fields|New options added to codelist|Change|Lookupvalue|Multiple fields|Multiple fields
50 +|Pump connection| |Field for the power connection of a pump|Add|LookupValue|tblObservations|METINGCODE 150
51 +|Matrix| |Added codelist options|Change|Lookupvalue|tblWatersamples|WsMatrix
52 +|Mesh size (mm)| |Field for the mesh size of a monitoring well filter|Add|Float|tblFiltertubes|FtMeshSize
53 +|Type|Project level|New codelist options|Change|Lookupvalue|tblProjects|PrType
54 +|Type|Finishing level|New codelist options|Change|Lookupvalue|tblFinishings|FiType
55 +|Measurement duration| |Field for the duration of a series of a measurements, mostly used to estimate the time when a tube is dry|Add|Float|tblObservations|METINGCODE 154 (Series), METINGCODE 153 (Stable value)
56 +|Pumped volume series| |Field for the total pumped volume during a single series|Add|Float|tblObservations|METINGCODE 152 (Series), METINGCODE 151 (Stable value)
57 +
58 +
3 3  **22-11-2021:**
4 4  
5 5  |**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
... ... @@ -41,3 +41,44 @@
41 41  |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoStreamlineGUID
42 42  |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLocations|(% colspan="1" rowspan="1" %)LcStreamlineGUID
43 43  |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblSublocations|(% colspan="1" rowspan="1" %)SlStreamlineGUID
100 +
101 +**07-10-2021:**
102 +
103 +|=(% colspan="1" rowspan="1" %)(((
104 +**Screen to add the extra field**
105 +)))|=(% colspan="1" rowspan="1" %)(((
106 +**Labeltext in English**
107 +)))|=(% colspan="1" rowspan="1" %)(((
108 +**Labeltext in Dutch**
109 +)))|=(% colspan="1" rowspan="1" %)(((
110 +**Examples of values and how it should be printed in a report.**
111 +)))|=(% colspan="1" rowspan="1" %)(((
112 +**Definition and process how this field will be used and when it will be filled.**
113 +)))|=(% colspan="1" rowspan="1" %)(((
114 +**Change/Add/Delete**
115 +)))|=(% colspan="1" rowspan="1" %)(((
116 +**DB Type**
117 +**(String (length) / Float / Lookupvalue / Integer / DateTime)**
118 +)))|=(% colspan="1" rowspan="1" %)(((
119 +**DBTable in dsFieldProject**
120 +)))|=(% colspan="1" rowspan="1" %)(((
121 +**DBFieldname in dsFieldProject**
122 +)))
123 +|(% colspan="1" rowspan="1" %)Measurement Points Details|(% colspan="1" rowspan="1" %)Sample Moisture|(% colspan="1" rowspan="1" %)Monstervochtigheid|(% colspan="1" rowspan="1" %)Dried out|(% colspan="1" rowspan="1" %)Explains humidity condition of measurment point|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpSampleHumidityCode
124 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Special conditions|(% colspan="1" rowspan="1" %)Bijzondere omstandigheden|(% colspan="1" rowspan="1" %)Normal, used standard protocol|(% colspan="1" rowspan="1" %)Description of deviation from protocol|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsSpecialConditions
125 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Field conditions|(% colspan="1" rowspan="1" %)Maaiveld omstandigheden|(% colspan="1" rowspan="1" %)Damp, easy to drill|(% colspan="1" rowspan="1" %)Description of field/location at time of sampling|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsFieldConditions
126 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - O2|(% colspan="1" rowspan="1" %)Kalibratie Zuurstof ~(%)|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 136 / WsCalibrationO2
127 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - CO2|(% colspan="1" rowspan="1" %)Kalibratie koolstofdioxine/CO2 (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 137 / WsCalibrationCO2
128 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Start-sampling time|(% colspan="1" rowspan="1" %)Tijdstip start bemonstering|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %)Time when the actual sampling has started|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsStartSampleTime
129 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling time|(% colspan="1" rowspan="1" %)Tijdstip einde monstername|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsPostSampleTime
130 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post- sampling O2|(% colspan="1" rowspan="1" %)Zuurstof einde monstername |(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 140 / WsPostSampleO2
131 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling CO2|(% colspan="1" rowspan="1" %)Koolstofdioxine/CO2 einde monstername  (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 141 / WsPostSampleCO2
132 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling air flow rate|(% colspan="1" rowspan="1" %)Debiet einde monstername |(% colspan="1" rowspan="1" %)0,3l/min|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 142 / WsPostSampleFlowRate
133 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling PID|(% colspan="1" rowspan="1" %)PID einde monstername |(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 143 / WsPostSamplePID
134 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling temperature|(% colspan="1" rowspan="1" %)Temperatuur einde monstername|(% colspan="1" rowspan="1" %)25C|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 144 / WsPostSampleTemperature
135 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air humidity|(% colspan="1" rowspan="1" %)Vochtigheid einde monstername|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 145 / WsPostSampleHumidity
136 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air pressure|(% colspan="1" rowspan="1" %)Luchtdruk einde monstername|(% colspan="1" rowspan="1" %)25hPa|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 146 / WsPostSamplePressure
137 +|(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode
138 +|(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber
139 +
140 +
TerraIndex
asd