Changes for page TerraIndex ReleaseNotes
Last modified by Roelof Zwaan on 2023/07/24 15:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.Ro binHuisman1 +XWiki.RoelofZwaan - Content
-
... ... @@ -1,5 +1,31 @@ 1 1 == Changes and updates: == 2 2 3 +**27-01-2022:** 4 + 5 +(% class="table-hover" %) 6 +|**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( 7 +**Change/Add/** 8 + 9 +**Delete** 10 +)))|**DB Type 11 +(String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** 12 +|Use of location| |To add the current use of the location to a measurement point|Add|Lookupvalue|tblMeasurementPoints|MpLocationUsageCode 13 +|Type|New codelist optios added |-|Change|Lookupvalue|tblMeasurementPoint|MpType 14 +|Interior location| |Yes / no field for if the sample is an interior location|Add|Lookupvalue|tblMeasurementPoints|MpIsIndoorsCode 15 +|FlowTypesSurfaceWater| |Describes the flowing pattern of the surface water sampling location|Add|Lookupvalue|tblObservations|METINGCODE 148 16 +|Location flow rate| |The flow rate of the sampling location|Add|Lookupvalue|tblObservations|METINGCODE 149 17 +|Special conditions| |Remark field for special sampling conditions to print in report|Add|String|tblWatersamples|JrStreamlineGUID 18 +|Pump type|Codelist used for several fields|New options added to codelist|Change|Lookupvalue|Multiple fields|Multiple fields 19 +|Pump connection| |Field for the power connection of a pump|Add|LookupValue|tblObservations|METINGCODE 150 20 +|Matrix| |Added codelist options|Change|Lookupvalue|tblWatersamples|WsMatrix 21 +|Mesh size (mm)| |Field for the mesh size of a monitoring well filter|Add|Float|tblFiltertubes|FtMeshSize 22 +|Type|Project level|New codelist options|Change|Lookupvalue|tblProjects|PrType 23 +|Type|Finishing level|New codelist options|Change|Lookupvalue|tblFinishings|FiType 24 +|Measurement duration| |Field for the duration of a series of a measurements, mostly used to estimate the time when a tube is dry|Add|Float|tblObservations|METINGCODE 154 (Series), METINGCODE 153 (Stable value) 25 +|Pumped volume series| |Field for the total pumped volume during a single series|Add|Float|tblObservations|METINGCODE 152 (Series), METINGCODE 151 (Stable value) 26 + 27 + 28 + 3 3 **22-11-2021:** 4 4 5 5 |**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** ... ... @@ -41,3 +41,44 @@ 41 41 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoStreamlineGUID 42 42 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLocations|(% colspan="1" rowspan="1" %)LcStreamlineGUID 43 43 |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblSublocations|(% colspan="1" rowspan="1" %)SlStreamlineGUID 70 + 71 +**07-10-2021:** 72 + 73 +|=(% colspan="1" rowspan="1" %)((( 74 +**Screen to add the extra field** 75 +)))|=(% colspan="1" rowspan="1" %)((( 76 +**Labeltext in English** 77 +)))|=(% colspan="1" rowspan="1" %)((( 78 +**Labeltext in Dutch** 79 +)))|=(% colspan="1" rowspan="1" %)((( 80 +**Examples of values and how it should be printed in a report.** 81 +)))|=(% colspan="1" rowspan="1" %)((( 82 +**Definition and process how this field will be used and when it will be filled.** 83 +)))|=(% colspan="1" rowspan="1" %)((( 84 +**Change/Add/Delete** 85 +)))|=(% colspan="1" rowspan="1" %)((( 86 +**DB Type** 87 +**(String (length) / Float / Lookupvalue / Integer / DateTime)** 88 +)))|=(% colspan="1" rowspan="1" %)((( 89 +**DBTable in dsFieldProject** 90 +)))|=(% colspan="1" rowspan="1" %)((( 91 +**DBFieldname in dsFieldProject** 92 +))) 93 +|(% colspan="1" rowspan="1" %)Measurement Points Details|(% colspan="1" rowspan="1" %)Sample Moisture|(% colspan="1" rowspan="1" %)Monstervochtigheid|(% colspan="1" rowspan="1" %)Dried out|(% colspan="1" rowspan="1" %)Explains humidity condition of measurment point|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpSampleHumidityCode 94 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Special conditions|(% colspan="1" rowspan="1" %)Bijzondere omstandigheden|(% colspan="1" rowspan="1" %)Normal, used standard protocol|(% colspan="1" rowspan="1" %)Description of deviation from protocol|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsSpecialConditions 95 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Field conditions|(% colspan="1" rowspan="1" %)Maaiveld omstandigheden|(% colspan="1" rowspan="1" %)Damp, easy to drill|(% colspan="1" rowspan="1" %)Description of field/location at time of sampling|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsFieldConditions 96 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - O2|(% colspan="1" rowspan="1" %)Kalibratie Zuurstof ~(%)|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 136 / WsCalibrationO2 97 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - CO2|(% colspan="1" rowspan="1" %)Kalibratie koolstofdioxine/CO2 (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 137 / WsCalibrationCO2 98 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Start-sampling time|(% colspan="1" rowspan="1" %)Tijdstip start bemonstering|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %)Time when the actual sampling has started|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsStartSampleTime 99 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling time|(% colspan="1" rowspan="1" %)Tijdstip einde monstername|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsPostSampleTime 100 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post- sampling O2|(% colspan="1" rowspan="1" %)Zuurstof einde monstername |(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 140 / WsPostSampleO2 101 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling CO2|(% colspan="1" rowspan="1" %)Koolstofdioxine/CO2 einde monstername (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 141 / WsPostSampleCO2 102 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling air flow rate|(% colspan="1" rowspan="1" %)Debiet einde monstername |(% colspan="1" rowspan="1" %)0,3l/min|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 142 / WsPostSampleFlowRate 103 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling PID|(% colspan="1" rowspan="1" %)PID einde monstername |(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 143 / WsPostSamplePID 104 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling temperature|(% colspan="1" rowspan="1" %)Temperatuur einde monstername|(% colspan="1" rowspan="1" %)25C|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 144 / WsPostSampleTemperature 105 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air humidity|(% colspan="1" rowspan="1" %)Vochtigheid einde monstername|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 145 / WsPostSampleHumidity 106 +|(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air pressure|(% colspan="1" rowspan="1" %)Luchtdruk einde monstername|(% colspan="1" rowspan="1" %)25hPa|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 146 / WsPostSamplePressure 107 +|(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode 108 +|(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber 109 + 110 +