5 | (% class="jumbotron" %) | ||
6 | ((( | ||
7 | (% class="container" %) | ||
8 | ((( | ||
9 | With this manual technique, the depth of the sediment can be measured. The dipstick has a foot. This is lowered vertically to the bottom of the water. Then the height of the water column above the foot is measured. | ||
10 | |||
11 | A dipstick is a dipstick on a fishing rod. The difference between a stick and a fishing rod lies in the approach to the water bottom from the side (rod) or from a boat (stick). If the foot is exchanged for a point, the thickness of the 'soft' (non-consolidated) sediment or silt layer can also be determined. | ||
12 | ))) | ||
13 | ))) | ||
14 | |||
15 | (% class="table-hover" %) | ||
16 | |(% colspan="4" style="text-align:center" %)**General information** | ||
17 | | |Name|Dipstick / sounding rod | ||
18 | | |Unit of measure and parameter|Height of water column in centimeters or thickness of the sludge layer | ||
19 | | |Nature technique|Physical | ||
20 | | |Place of application|in situ | ||
21 | | |Detection Mode|Drilling / stabbing or measurement at ground level/water bottom | ||
22 | | |Applicable in separate layers|new | ||
23 | | |Land soil/water bottom|water bottom | ||
24 | | |Step in the data collection chain|((( | ||
25 | * Measure | ||
26 | * Data collection and evaluation | ||
27 | ))) | ||
28 | | |Moment of availability results|Measurement results are available in the field | ||
29 | | |Technology development phase|Applied routinely | ||
30 | | |Method of purchasing|as service or as a device | ||
31 | | |General description of the implementation method|((( | ||
32 | The dipstick with foot is sunk down to the sludge. There is a light version that is placed with a fishing rod or a heavier version that is carefully placed from a boat or into the water. The height of the water column can then be read on the basis of a measurement on the stick. This means that the depth at which the water bed is located is known on site. | ||
33 | |||
34 | With a sounding rod the same can be done from the side up to a maximum waterway width of 6 m. | ||
35 | |||
36 | If foot is exchanged for a point, the thickness of sediment or silt layers can also be determined. | ||
37 | ))) | ||
38 | | |Working principle|The height of the water column can be measured by means of a graduation on the stick. A fishing rod provides a good vertical measurement from the shore. | ||
39 | | |Point / line measurement / volume measurement|Point measurement | ||
40 | | |((( | ||
41 | Technical specifications | ||
42 | |||
43 | (including accuracy) | ||
44 | )))|((( | ||
45 | Dipstick is made of aluminum; periodic calibration prevents measurement errors. | ||
46 | |||
47 | Accuracy: ± 1 to 2 centimeters (depending on the wave action) | ||
48 | ))) | ||
49 | | |Typical depth range|((( | ||
50 | Dipstick maximum 5 meters | ||
51 | |||
52 | Leveling rod maximum 2 meters. | ||
53 | Sensitivity independent of depth | ||
54 | ))) | ||
55 | | |Time properties|A single measurement can be performed in a short time. | ||
56 | | |Measuring rate|From 1 minute per measurement | ||
57 | | |Presentation results|Observation is directly readable on the dipstick; several measurements form a cross section. | ||
58 | | |Cost|Vary very strongly per provider and conditions in the field: from € 20 to € 150 per measurement | ||
59 | |(% colspan="4" style="text-align:center" %)((( | ||
60 | **User information** | ||
61 | ))) | ||
62 | | |availabilty|large number of providers | ||
63 | | |Is technology often used?|Very organized | ||
64 | | |Research phase in which technology can be applied|((( | ||
65 | * Explore | ||
66 | * Design | ||
67 | * Check | ||
68 | ))) | ||
69 | | |Verification measurements / calibration measurements|are often used | ||
70 | | |Frequently used application in practice|Gauging in and out of smaller waterways and of sediment or sludge layer thickness | ||
71 | | |Suitability|Suitable for manually sounding waterways that are not too large. | ||
72 | | |Practical experiences in the Netherlands|It is used very regularly, mainly by water boards or consultancy firms throughout the Netherlands. Experience shows that the accuracy strongly depends on the circumstances and the sounder. Manual gauging usually gives a good idea of the thickness of the sludge layer. | ||
73 | | |“Dos“|Measuring level with a higher measurement density at the slopes | ||
74 | | |“Don'ts”|Use as little pressure as possible when probing to press the foot into the sludge layer. | ||
75 | |||
76 | = References = | ||
77 | |||
78 | * [[Stowa>>url:http://linkmanager.bodemrichtlijn.nl/Connect/iryfzv]] | ||
79 | * [[Stowa: INTELLIGENTE PEILSTOK>>url:http://linkmanager.bodemrichtlijn.nl/Connect/kyocgw]] | ||
80 | * [[SIKB-protocol 2003>>url:http://linkmanager.bodemrichtlijn.nl/Connect/gdbwil]] | ||
81 | ))) | ||
82 | |||
83 | (% class="col-xs-12 col-sm-4" %) | ||
84 | ((( | ||
85 | (% class="box" %) | ||
86 | ((( | ||
87 | = Dipstick = | ||
88 | |||
89 | [[image:peilhengel.jpg||alt="image.jpg"]] | ||
90 | |||
91 | |=(% scope="row" %)Image|[[Dipstick>>https://www-bodemrichtlijn-nl.translate.goog/Connect/bodemonderzoek/fts078-1?_x_tr_sl=nl&_x_tr_tl=en&_x_tr_hl=nl&_x_tr_pto=wapp]] | ||
92 | ))) | ||
93 | |||
94 | (% class="box" %) | ||
95 | ((( | ||
96 | **Contents** | ||
97 | |||
98 | {{toc/}} | ||
99 | ))) | ||
100 | ))) | ||
101 | ))) |