8 (((
9 With this manual technique, the depth of the sediment can be measured. The dipstick has a foot. This is lowered vertically to the bottom of the water. Then the height of the water column above the foot is measured.
10
11 A dipstick is a dipstick on a fishing rod. The difference between a stick and a fishing rod lies in the approach to the water bottom from the side (rod) or from a boat (stick). If the foot is exchanged for a point, the thickness of the 'soft' (non-consolidated) sediment or silt layer can also be determined.
12 )))
13 )))
14
15 (% class="table-hover" %)
16 |(% colspan="4" style="text-align:center" %)**General information**
17 | |Name|Dipstick / sounding rod
18 | |Unit of measure and parameter|Height of water column in centimeters or thickness of the sludge layer
19 | |Nature technique|Physical
20 | |Place of application|in situ
21 | |Detection Mode|Drilling / stabbing or measurement at ground level/water bottom
22 | |Applicable in separate layers|new
23 | |Land soil/water bottom|water bottom
24 | |Step in the data collection chain|(((
25 * Measure
26 * Data collection and evaluation
27 )))
28 | |Moment of availability results|Measurement results are available in the field
29 | |Technology development phase|Applied routinely
30 | |Method of purchasing|as service or as a device
31 | |General description of the implementation method|(((
32 The dipstick with foot is sunk down to the sludge. There is a light version that is placed with a fishing rod or a heavier version that is carefully placed from a boat or into the water. The height of the water column can then be read on the basis of a measurement on the stick. This means that the depth at which the water bed is located is known on site.
33
34 With a sounding rod the same can be done from the side up to a maximum waterway width of 6 m.
35
36 If foot is exchanged for a point, the thickness of sediment or silt layers can also be determined.
37 )))
38 | |Working principle|The height of the water column can be measured by means of a graduation on the stick. A fishing rod provides a good vertical measurement from the shore.
39 | |Point / line measurement / volume measurement|Point measurement
40 | |(((
41 Technical specifications
42
43 (including accuracy)
44 )))|(((
45 Dipstick is made of aluminum; periodic calibration prevents measurement errors.
46
47 Accuracy: ± 1 to 2 centimeters (depending on the wave action)
48 )))
49 | |Typical depth range|(((
50 Dipstick maximum 5 meters
51
52 Leveling rod maximum 2 meters.
53 Sensitivity independent of depth
54 )))
55 | |Time properties|A single measurement can be performed in a short time.
56 | |Measuring rate|From 1 minute per measurement
57 | |Presentation results|Observation is directly readable on the dipstick; several measurements form a cross section.
58 | |Cost|Vary very strongly per provider and conditions in the field: from € 20 to € 150 per measurement
59 |(% colspan="4" style="text-align:center" %)(((
60 **User information**
61 )))
62 | |availabilty|large number of providers
63 | |Is technology often used?|Very organized
64 | |Research phase in which technology can be applied|(((
65 * Explore
66 * Design
67 * Check
68 )))
69 | |Verification measurements / calibration measurements|are often used
70 | |Frequently used application in practice|Gauging in and out of smaller waterways and of sediment or sludge layer thickness
71 | |Suitability|Suitable for manually sounding waterways that are not too large.
72 | |Practical experiences in the Netherlands|It is used very regularly, mainly by water boards or consultancy firms throughout the Netherlands. Experience shows that the accuracy strongly depends on the circumstances and the sounder. Manual gauging usually gives a good idea of ​​the thickness of the sludge layer.
73 | |“Dos“|Measuring level with a higher measurement density at the slopes
74 | |“Don'ts”|Use as little pressure as possible when probing to press the foot into the sludge layer.
75
76 = References =
77
78 * [[Stowa>>url:http://linkmanager.bodemrichtlijn.nl/Connect/iryfzv]]
79 * [[Stowa: INTELLIGENTE PEILSTOK>>url:http://linkmanager.bodemrichtlijn.nl/Connect/kyocgw]]
80 * [[SIKB-protocol 2003>>url:http://linkmanager.bodemrichtlijn.nl/Connect/gdbwil]]
81 )))
82
83 (% class="col-xs-12 col-sm-4" %)
84 (((
85 (% class="box" %)
86 (((
87 = Dipstick =
88
89 [[image:peilhengel.jpg||alt="image.jpg"]]
90
91 |=(% scope="row" %)Image|[[Dipstick>>https://www-bodemrichtlijn-nl.translate.goog/Connect/bodemonderzoek/fts078-1?_x_tr_sl=nl&_x_tr_tl=en&_x_tr_hl=nl&_x_tr_pto=wapp]]
92 )))
93
94 (% class="box" %)
95 (((
96 **Contents**
97
98 {{toc/}}
99 )))
100 )))
101 )))
TerraIndex
asd