Changes for page PetroFLAG analyzer
Last modified by TerraIndex TerraIndex on 2021/09/30 15:20
From version 3.2
edited by TerraIndex TerraIndex
on 2021/05/28 11:46
on 2021/05/28 11:46
Change comment:
Added tag [PID,PetroFLAG analyzer]
To version 4.1
edited by TerraIndex TerraIndex
on 2021/07/16 13:25
on 2021/07/16 13:25
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -PetroFLAG analy zer1 +PetroFLAG analyseapparaat - Content
-
... ... @@ -6,7 +6,7 @@ 6 6 ((( 7 7 (% class="container" %) 8 8 ((( 9 -Dexsil ’s PetroFLAG Total Petroleum Hydrocarbon (TPH) in Soil System isan on-site testfordeterminingthe totalpetroleumhydrocarbonsinsoil.It is easyto use,inexpensive,and environmentally safe.The PetroFLAGSystemdoesnotdistinguish between aliphaticandaromaticydrocarbons,butquantifiesall oils,greases,anduelsas totalhydrocarbons. Analysisisperformedusing a 10 gramsoil sampleandthreeeasysteps: extraction, filtration,andanalysis.9 +Dexsil's PetroFLAG Total Petroleum Hydrocarbon (TPH) in Soil System is een on-site testkit voor het bepalen van de totale hoeveelheid aardoliekoolwaterstoffen in de bodem. Het is gemakkelijk te gebruiken, goedkoop en milieuvriendelijk. Het PetroFLAG-systeem maakt geen onderscheid tussen alifatische en aromatische koolwaterstoffen, maar kwantificeert alle oliën, vetten en brandstoffen als totale koolwaterstoffen. Analyse wordt uitgevoerd met behulp van een grondmonster van 10 gram en drie eenvoudige stappen: extractie, filtratie en analyse. 10 10 ))) 11 11 ))) 12 12 ... ... @@ -20,7 +20,6 @@ 20 20 21 21 === Response factors and method detection limits for common hydrocarbons === 22 22 23 -(% class="table-hover" %) 24 24 |=Hydrocarbon type|=Method detection limit (ppm)|=Response setting 25 25 |Transformer oil|15|10 26 26 |Grease|15|9 ... ... @@ -138,7 +138,7 @@ 138 138 139 139 If you wish to exit the read mode, push the <NEXT> key and the operation is returned to the MAIN MENU. The <NEXT> key is also used to skip a step where a menu selection is required. To change a flashing menu option, push the <SCROLL> key while the option is flashing. To store the currently flashing menu choice, push the <SELECT> key. This stores the current choice and moves the flashing cursor to the next program mode.[[[2]>>url:https://www.equipcoservices.com/pdf/manuals/dexsil_petroflag_system.pdf]] 140 140 141 -== Selecting a calibration curve ==140 +== Choosing a calibration curve == 142 142 143 143 Either of the two calibration curves, identified as "1C" and "2C", can be selected from the MAIN MENU. From either calibration curve any response factor can be selected. To change the response factor or to recalibrate the unit, use the <NEXT> key to enter the MAIN MENU screen. Immediately upon entering this menu three decimal points and the response factor are displayed. Next, the first two characters on the screen indicates the calibration curve that is currently selected (“1C” or “2C”) is displayed. They will blink, indicating that a new curve may be selected. Use the <SCROLL> key to scroll to the next calibration curve. Push the <SELECT/OFF> key to select the curve. The response factor will then blink. Use the <“SCROLL> key to scroll to the desired response factor for the target analyte and press the <SELECT/OFF> key.[[[2]>>url:https://www.equipcoservices.com/pdf/manuals/dexsil_petroflag_system.pdf]] 144 144