Wiki source code of TerraIndex ReleaseNotes
Version 2.2 by Roelof Zwaan on 2022/03/02 10:12
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
1.1 | 1 | == Changes and updates: == |
| 2 | |||
| |
2.2 | 3 | **27-01-2022:** |
| 4 | |||
| 5 | (% class="table-hover" %) | ||
| 6 | |**Labeltext in English**|**Remarks**|**Definition and process how this field will be used and when it will be filled.**|((( | ||
| 7 | **Change/Add/** | ||
| 8 | |||
| 9 | **Delete** | ||
| 10 | )))|**DB Type | ||
| 11 | (String (length) / Float / Lookupvalue / Integer / DateTime)**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** | ||
| 12 | |Use of location| |To add the current use of the location to a measurement point|Add|Lookupvalue|tblMeasurementPoints|MpLocationUsageCode | ||
| 13 | |Type|New codelist optios added |-|Change|Lookupvalue|tblMeasurementPoint|MpType | ||
| 14 | |Interior location| |Yes / no field for if the sample is an interior location|Add|Lookupvalue|tblMeasurementPoints|MpIsIndoorsCode | ||
| 15 | |FlowTypesSurfaceWater| |Describes the flowing pattern of the surface water sampling location|Add|Lookupvalue|tblObservations|METINGCODE 148 | ||
| 16 | |Location flow rate| |The flow rate of the sampling location|Add|Lookupvalue|tblObservations|METINGCODE 149 | ||
| 17 | |Special conditions| |Remark field for special sampling conditions to print in report|Add|String|tblWatersamples|JrStreamlineGUID | ||
| 18 | |Pump type|Codelist used for several fields|New options added to codelist|Change|Lookupvalue|Multiple fields|Multiple fields | ||
| 19 | |Pump connection| |Field for the power connection of a pump|Add|LookupValue|tblObservations|METINGCODE 150 | ||
| 20 | |Matrix| |Added codelist options|Change|Lookupvalue|tblWatersamples|WsMatrix | ||
| 21 | |Mesh size (mm)| |Field for the mesh size of a monitoring well filter|Add|Float|tblFiltertubes|FtMeshSize | ||
| 22 | |Type|Project level|New codelist options|Change|Lookupvalue|tblProjects|PrType | ||
| 23 | |Type|Finishing level|New codelist options|Change|Lookupvalue|tblFinishings|FiType | ||
| 24 | |Measurement duration| |Field for the duration of a series of a measurements, mostly used to estimate the time when a tube is dry|Add|Float|tblObservations|METINGCODE 154 (Series), METINGCODE 153 (Stable value) | ||
| 25 | |Pumped volume series| |Field for the total pumped volume during a single series|Add|Float|tblObservations|METINGCODE 152 (Series), METINGCODE 151 (Stable value) | ||
| 26 | |||
| 27 | |||
| 28 | |||
| |
1.1 | 29 | **22-11-2021:** |
| 30 | |||
| 31 | |**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject** | ||
| 32 | | | | | | | | | | | | ||
| 33 | |Soil samples|Length core sampler|Lengte steekbuis (mm)|Length core sampler (mm)|The length of a core sampler may vary and defines volume| |Add|Integer|tblJars|JrLengthCoreSampler | ||
| 34 | |Measurement Point|Diameter|Diameter (mm)|Diameter (mm)|(% colspan="2" %)Information is available on layer level, but may sometimes be consistent over the entire measurement point|Add|Integer|tblMeasurementPoints|MpDiameter | ||
| 35 | |Air Samples packaging|Placed in serie|In serie geplaatst|Yes/no|Two packages for air samples can be placed in serie or not| |Add|Lookupvalue (Yes/No)|tblBottles|BoPlacedInSerie | ||
| 36 | |Water samples|Surrounding humidity|Omgevingsvochtigheid|Licht vochtig, Zeer vochtig, Vochtig op bodem, Vochtig op plaatsen|The circumstances when sampling| |Add|Codelist|((( | ||
| 37 | * tblObservations | ||
| 38 | * tblWatersampleMeasurements | ||
| 39 | )))|Metingcode: 147 / WsSurroundingHumidity | ||
| 40 | |||
| 41 | **18-10-2021:** | ||
| 42 | |||
| 43 | |=(% colspan="1" rowspan="1" %)((( | ||
| 44 | **Labeltext in English** | ||
| 45 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 46 | **Remarks** | ||
| 47 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 48 | **Definition and process how this field will be used and when it will be filled.** | ||
| 49 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 50 | **Change/Add/Delete** | ||
| 51 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 52 | **DB Type** | ||
| 53 | **(String (length) / Float / Lookupvalue / Integer / DateTime)** | ||
| 54 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 55 | **DBTable in dsFieldProject** | ||
| 56 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 57 | **DBFieldname in dsFieldProject** | ||
| 58 | ))) | ||
| 59 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblProjects|(% colspan="1" rowspan="1" %)PrStreamlineGUID | ||
| 60 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpStreamlineGUID | ||
| 61 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblWaterSample |(% colspan="1" rowspan="1" %)WsStreamlineGUID | ||
| 62 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFiltertubes|(% colspan="1" rowspan="1" %)FtStreamlineGUID | ||
| 63 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLayers|(% colspan="1" rowspan="1" %)LaStreamlineGUID | ||
| 64 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrStreamlineGUID | ||
| 65 | |(% colspan="1" rowspan="1" %)PackagingStreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrPackagingStreamlineGUID | ||
| 66 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblFinishings|(% colspan="1" rowspan="1" %)FiStreamlineGUID | ||
| 67 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoStreamlineGUID | ||
| 68 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblLocations|(% colspan="1" rowspan="1" %)LcStreamlineGUID | ||
| 69 | |(% colspan="1" rowspan="1" %)StreamlineGUID|(% colspan="1" rowspan="1" %)Does not have to be unique|(% colspan="1" rowspan="1" %)To facilate synchronisation between Streamline and Classic|(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)Unique identifier |(% colspan="1" rowspan="1" %)tblSublocations|(% colspan="1" rowspan="1" %)SlStreamlineGUID | ||
| |
2.1 | 70 | |
| 71 | **07-10-2021:** | ||
| 72 | |||
| 73 | |=(% colspan="1" rowspan="1" %)((( | ||
| 74 | **Screen to add the extra field** | ||
| 75 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 76 | **Labeltext in English** | ||
| 77 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 78 | **Labeltext in Dutch** | ||
| 79 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 80 | **Examples of values and how it should be printed in a report.** | ||
| 81 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 82 | **Definition and process how this field will be used and when it will be filled.** | ||
| 83 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 84 | **Change/Add/Delete** | ||
| 85 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 86 | **DB Type** | ||
| 87 | **(String (length) / Float / Lookupvalue / Integer / DateTime)** | ||
| 88 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 89 | **DBTable in dsFieldProject** | ||
| 90 | )))|=(% colspan="1" rowspan="1" %)((( | ||
| 91 | **DBFieldname in dsFieldProject** | ||
| 92 | ))) | ||
| 93 | |(% colspan="1" rowspan="1" %)Measurement Points Details|(% colspan="1" rowspan="1" %)Sample Moisture|(% colspan="1" rowspan="1" %)Monstervochtigheid|(% colspan="1" rowspan="1" %)Dried out|(% colspan="1" rowspan="1" %)Explains humidity condition of measurment point|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblMeasurementPoint|(% colspan="1" rowspan="1" %)MpSampleHumidityCode | ||
| 94 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Special conditions|(% colspan="1" rowspan="1" %)Bijzondere omstandigheden|(% colspan="1" rowspan="1" %)Normal, used standard protocol|(% colspan="1" rowspan="1" %)Description of deviation from protocol|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsSpecialConditions | ||
| 95 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Field conditions|(% colspan="1" rowspan="1" %)Maaiveld omstandigheden|(% colspan="1" rowspan="1" %)Damp, easy to drill|(% colspan="1" rowspan="1" %)Description of field/location at time of sampling|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (2000)|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsFieldConditions | ||
| 96 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - O2|(% colspan="1" rowspan="1" %)Kalibratie Zuurstof ~(%)|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 136 / WsCalibrationO2 | ||
| 97 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Calibration - CO2|(% colspan="1" rowspan="1" %)Kalibratie koolstofdioxine/CO2 (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %)Filled in when performing the leaking test before prepumping|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 137 / WsCalibrationCO2 | ||
| 98 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Start-sampling time|(% colspan="1" rowspan="1" %)Tijdstip start bemonstering|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %)Time when the actual sampling has started|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsStartSampleTime | ||
| 99 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling time|(% colspan="1" rowspan="1" %)Tijdstip einde monstername|(% colspan="1" rowspan="1" %)11:30:00|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblWaterSample|(% colspan="1" rowspan="1" %)WsPostSampleTime | ||
| 100 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post- sampling O2|(% colspan="1" rowspan="1" %)Zuurstof einde monstername |(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 140 / WsPostSampleO2 | ||
| 101 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling CO2|(% colspan="1" rowspan="1" %)Koolstofdioxine/CO2 einde monstername (ppm)|(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 141 / WsPostSampleCO2 | ||
| 102 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling air flow rate|(% colspan="1" rowspan="1" %)Debiet einde monstername |(% colspan="1" rowspan="1" %)0,3l/min|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 142 / WsPostSampleFlowRate | ||
| 103 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling PID|(% colspan="1" rowspan="1" %)PID einde monstername |(% colspan="1" rowspan="1" %)25ppm|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 143 / WsPostSamplePID | ||
| 104 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post-sampling temperature|(% colspan="1" rowspan="1" %)Temperatuur einde monstername|(% colspan="1" rowspan="1" %)25C|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 144 / WsPostSampleTemperature | ||
| 105 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air humidity|(% colspan="1" rowspan="1" %)Vochtigheid einde monstername|(% colspan="1" rowspan="1" %)25%|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 145 / WsPostSampleHumidity | ||
| 106 | |(% colspan="1" rowspan="1" %)Air sample details|(% colspan="1" rowspan="1" %)Post sampling air pressure|(% colspan="1" rowspan="1" %)Luchtdruk einde monstername|(% colspan="1" rowspan="1" %)25hPa|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)float|(% colspan="1" rowspan="1" %)tblObservations/tblWatersampleMeasurements|(% colspan="1" rowspan="1" %)Metingcode: 146 / WsPostSamplePressure | ||
| 107 | |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode | ||
| 108 | |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber | ||
| 109 | |||
| 110 |