From version < 5.4 >
edited by Richard Dyer
on 2021/11/22 10:49
To version < 5.2 >
edited by Roelof Zwaan
on 2021/11/22 10:25
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.RichardDyer
1 +XWiki.RoelofZwaan
Content
... ... @@ -10,9 +10,9 @@
10 10  
11 11  **[[Field database description>>attach:20150224 Field Database Description (3).docx]]**
12 12  
13 -[[(% class="wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink" %)**dsFieldproject format XSD file**>>attach:dsFieldProject.xsd]]
13 +[[(% class="wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink" %)**dsFieldproject format XSD file**>>attach:dsFieldProject.xsd]]
14 14  
15 -[[(% class="wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink" %)**Codelookup excel list**>>attach:20200619 Codelookup.xlsx]]
15 +[[(% class="wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink wikiattachmentlink" %)**Codelookup excel list**>>attach:20200619 Codelookup.xlsx]]
16 16  )))
17 17  )))
18 18  
... ... @@ -93,15 +93,6 @@
93 93  
94 94  == Changes and updates: ==
95 95  
96 -**22-11-2021:**
97 -
98 -|**Screen to add the extra field**|**Labeltext of field in English**|**Labeltext in Dutch**|**Examples of values and how it should be printed in a report.**|**Definition and process how this field will be used and when it will be filled.**|**Codelist CategoryID**|**Change/Add/Delete**|**DB Type**|**DBTable in dsFieldProject**|**DBFieldname in dsFieldProject**
99 -| | | | | | | | | |
100 -|Soil samples|JrLengthCoreSampler|Lengte steekbuis (mm)|Length core sampler (mm)|The length of a core sampler may vary and defines volume| |Add|Integer|tblJars|JrLengthCoreSampler
101 -|Measurement Point|MpDiameter|Diameter (mm)|Diameter (mm)|(% colspan="2" %)Information is available on layer level, but may sometimes be consistent over the enitre measurement point|Add|Integer|tblMeasurementPoints|MpDiameter
102 -|Air Samples packaging|Placed in serie|In serie geplaatst|Yes/no|Two packagings for air samples can be placed in serie or not| |Add|Lookupvalue (Yes/No)|tblBottles|BoPlacedInSerie
103 -|Water samples|Surrounding humidity|Omgevingsvochtigheid|Licht vochtig, Zeer vochtig, Vochtig op bodem, Vochtig op plaatsen|The circumstances whan sampling| |Add|Codelist|tblWaterSample|WsSurroundingHumidity
104 -
105 105  **18-10-2021:**
106 106  
107 107  (% class="table-hover" style="height:1452px; width:1050px" %)
... ... @@ -173,6 +173,7 @@
173 173  |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Sample type|(% colspan="1" rowspan="1" %)Monstertype|(% colspan="1" rowspan="1" %)regular sample/transport blind/environment blind|(% colspan="1" rowspan="1" %)To select the type of support used in the sampling process|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)lookupvalue|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoSampleTypeCode
174 174  |(% colspan="1" rowspan="1" %)Air samples Packaging|(% colspan="1" rowspan="1" %)Reference number|(% colspan="1" rowspan="1" %)Referentienummer|(% colspan="1" rowspan="1" %)088D235D123|(% colspan="1" rowspan="1" %)As secundary to barcode. Supports have both a barcode and a reference|(% colspan="1" rowspan="1" %)Add Field|(% colspan="1" rowspan="1" %)string (10)|(% colspan="1" rowspan="1" %)tblBottles|(% colspan="1" rowspan="1" %)BoReferenceNumber
175 175  
167 +
176 176  **6-8-2021:**
177 177  
178 178  (% class="table-hover" %)
... ... @@ -184,6 +184,7 @@
184 184  |(% colspan="1" rowspan="1" %)Watersample details|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)reden pompen beeindigd|(% colspan="1" rowspan="1" %)518 (categoryID: 200)|(% colspan="1" rowspan="1" %)Add Codelist item,|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)peilbuis is droog
185 185  |(% colspan="1" rowspan="1" %)Meetpunt details|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)reden boring gestopt|(% colspan="1" rowspan="1" %)236 (categoryID: 236)|(% colspan="1" rowspan="1" %)Add Codelist item|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)water aangetroffen
186 186  
179 +
187 187  **1-6-2021:**
188 188  
189 189  (% class="table-hover" %)
... ... @@ -239,6 +239,7 @@
239 239  |(% colspan="1" rowspan="1" %)Water Sample - series|(% colspan="1" rowspan="1" %)Turbidity serie|(% colspan="1" rowspan="1" %)In France , Spain (and Germany)Ā  they don't use NTU to describe turbidity but appreciations
240 240  The same appreciations that already exist for the feld "turbidiy" from Watersample should also exist for the series|(% colspan="1" rowspan="1" %)252|(% colspan="1" rowspan="1" %)add|(% colspan="1" rowspan="1" %)Helderheid reeks|(% colspan="1" rowspan="1" %)Codelist|(% colspan="1" rowspan="1" %)String (10)|(% colspan="1" rowspan="1" %)METINGCODE|(% colspan="1" rowspan="1" %)METINGCODE
241 241  
235 +
242 242  **20-04-2021:**
243 243  
244 244  |(% colspan="1" rowspan="1" %)**Change/Add/Delete**|(% colspan="1" rowspan="1" %)**Remarks, Questions with answers and feedback of the status and the field info.**|(% colspan="1" rowspan="1" %)**Labeltext in Dutch**|(% colspan="1" rowspan="1" %)**CategoryID**|(% colspan="1" rowspan="1" %)**Input type**|(% colspan="1" rowspan="1" %)**DB Type**|(% colspan="1" rowspan="1" %)**(String (length) / Float / Lookupvalue / Integer / DateTime)**|(% colspan="1" rowspan="1" %)**tblObservations/**|(% colspan="1" rowspan="1" %)**DBFieldname in dsFieldProject**
... ... @@ -263,6 +263,7 @@
263 263  |(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %)The weatherconditions during the visit to the location|(% colspan="1" rowspan="1" %)Weersomstandigheden|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Text input|(% colspan="2" rowspan="1" %)String(2000)|(% colspan="1" rowspan="1" %)tblLocationVisits|(% colspan="1" rowspan="1" %)LvWeatherConditionsDescription
264 264  |(% colspan="1" rowspan="1" %)Add|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)nvt|(% colspan="2" rowspan="1" %)datetime|(% colspan="1" rowspan="1" %)tblLocationVisits|(% colspan="1" rowspan="1" %)LvDateLastChanged
265 265  
260 +
266 266  **10-3-2021:**
267 267  
268 268  (% class="table-hover" %)
... ... @@ -319,6 +319,7 @@
319 319  * tblWatersampleMeasurements
320 320  )))|(% colspan="1" rowspan="1" %)METING CODE: 118
321 321  
317 +
322 322  (% class="table-hover" %)
323 323  |(% colspan="1" rowspan="1" %)**Change/Add/Delete**|(% colspan="1" rowspan="1" %)**Remarks, Questions with answers and feedback of the status and the field info.**|(% colspan="1" rowspan="1" %)**Labeltext in Dutch**|(% colspan="1" rowspan="1" %)**CategoryID**|(% colspan="1" rowspan="1" %)**DB Type**|(% colspan="1" rowspan="1" %)**Table**|(% colspan="1" rowspan="1" %)**Column**
324 324  |(% colspan="1" rowspan="1" %)Add column|(% colspan="1" rowspan="1" %)When a sample has a strong hydrocarbon odor a measure of Total Petroleum Hydrocarbons (TPH) is performed in the field with a PetroFLAG analyzer. This field is meant to register that value.|(% colspan="1" rowspan="1" %)PetroFLAGĀ® Analyzer (ppmv)|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Float|(% colspan="1" rowspan="1" %)tblJars|(% colspan="1" rowspan="1" %)JrPetroFLAGAnalyzerValue
... ... @@ -330,6 +330,7 @@
330 330  |(% colspan="1" rowspan="1" %)Add Observation|(% colspan="1" rowspan="1" %)When a gauging tube is purged, it can be done in two ways. Static: the intake depth is left at a set location. Dynamic: the hose intake depth is manually varied by moving the hose up and down.|(% colspan="1" rowspan="1" %)Afpomp methode|(% colspan="1" rowspan="1" %)263|(% colspan="1" rowspan="1" %)String(10)|(% colspan="1" rowspan="1" %)tblObservations|(% colspan="1" rowspan="1" %)WsPurgeModeCode/Metingcode: 123
331 331  |(% colspan="1" rowspan="1" %)Add Observation|(% colspan="1" rowspan="1" %)The total voltage that is measured on a water sample. So that is Redox + Standard. This is used in Germany to give adivice on the sample|(% colspan="1" rowspan="1" %)Totale voltage (mV)|(% colspan="1" rowspan="1" %) |(% colspan="1" rowspan="1" %)Float|(% colspan="1" rowspan="1" %)tblObservations|(% colspan="1" rowspan="1" %)WsTotalVoltage/Metingcode: 124
332 332  
329 +
333 333  **11-8-2020:**
334 334  
335 335  (% class="table-hover" %)
... ... @@ -358,6 +358,7 @@
358 358  Ground filter prefilter|(% colspan="1" rowspan="1" %)255- Filtering method for the bottle
359 359  |(% colspan="1" rowspan="1" %)tblConcernedCompanies|(% colspan="1" rowspan="1" %)CcChamberOfCommerceNr Varchar(50)|(% colspan="1" rowspan="1" %)Chamber of Commerce Nr|(% colspan="1" rowspan="1" %)-|(% colspan="1" rowspan="1" %)-|(% colspan="1" rowspan="1" %)-
360 360  
358 +
361 361  **10-7-2020:**
362 362  
363 363  (% class="table-hover" %)
... ... @@ -678,6 +678,7 @@
678 678  * Hoog
679 679  )))|(% colspan="1" rowspan="1" %)244
680 680  
679 +
681 681  **05-Aug-2019**
682 682  
683 683  Additional **ISO14688** fields
TerraIndex
asd